Millenium Signatures MS-510 Скачать руководство пользователя страница 2

510 SOLID STATE CONTROLLED POWER UNIT

MARKING AND OPERATING PROCEDURES

You have just purchased the industry’s most durable, technically advanced electro-

chemical marking power unit available today.  Please review the following operating 

procedures to prevent damage to your unit, and to achieve good marking results.

FEATURES:

 

• “AC-DC” Selection 

 

• “Low/High” Voltage Selection.  Note:  there are three positions on this switch. 

 

UP=HIGH, MIDDLE=NO POWER, DOWN=LOW 

 

• “Deep Etch” capabilities of up to .005” 

 

• “Automatic Mode” Selection 

 

• Two individually timed selector switches, calibrated from 0.2 to 35 seconds to  

 

automatically control the machine cycle time 

 

• “Power Pulse” Selection 

 

• Two individually timed selector switches, calibrated from 0.2 to 2.4 seconds to  

 

automatically control power pulsing 

 

• Foot Pedal, Manual, or Automatic Operator Selection 

 

• “High Power” indicator light 

 

•2- “3.0” Amp Fuses for power unit protection against overloading 

 

• Smooth action “Power Selection Switch” 

 

• Built in alarm to alert the operator of amperage overload 

 

• Two individual “Rotary Time Selectors”

NOTE: 

Avoid short circuits.  (See illustration 1-A) Do not cross the leads or make 

contact between the marker and the grounded surface when both surfaces are bare. Your 

power unit is designed to work from a 110-120 AC volt outlet only. (220 is available 

upon request).

SET-UP AND OPERATION

The Millennium Signatures Marking Systems 

510 Power Unit is designed to operate manually, 

semi-automatically or automatically.  Follow the 

set-up and operating instructions given for your 

application.

MANUAL SET-UP:

A)

 Plug your unit into a 110-120 AC Volt outlet 

only. 

  

     ILLUSTRATION 1-A

Содержание MS-510

Страница 1: ...Model MS 510 Instruction Manual 4179 7 Harvester Road Burlington Ontario Canada L7L 5M4 Phone 905 639 0909 Fax 905 639 0919 E mail info millenniumsignatures com ...

Страница 2: ...ated from 0 2 to 2 4 seconds to automatically control power pulsing Foot Pedal Manual or Automatic Operator Selection High Power indicator light 2 3 0 Amp Fuses for power unit protection against overloading Smooth action Power Selection Switch Built in alarm to alert the operator of amperage overload Two individual Rotary Time Selectors NOTE Avoid short circuits See illustration 1 A Do not cross t...

Страница 3: ...ures 9 11 5 4 1 10 respectively Illustration 3 A Turn the power unit on Choose the proper current setting AC produces a black mark DC produces a white mark and is also used for deep etching A white mark may be desirable for etching various materials such as black oxide B The 510 B Power Unit is equipped with twelve power settings With the voltage switch Fig 5 set to LOW the settings on the POWER S...

Страница 4: ...ropriate monopad on the marking head and attach the insert stencil cap stencil or flat stencil as required E Place the long tube from the 152 electrolyte pump in the open bottle of electrolyte Prime the pump by rotating quickly clockwise The pump is adjusted by the small set screw on the stop below the lever SEMI AUTOMATIC OPERATION A Flip the power toggle switch up to turn the unit on B Choose th...

Страница 5: ...ON controls the length of time the current is delivered to the marking head The dial marked OFF controls the length of time the current flow is interrupted even through the marking head remains in contact with the substrate The greater the number the longer the times in both cases An amp meter FIG 8 has been provided for visual confirmation of the current These timers are used for applications tha...

Страница 6: ...main up for the selected time and then repeat this cycle until the machine is shut off HOUSEKEEPING It is important to keep your unit free of oxidation and salt build up This will ensure years of dependable trouble free operation A Keep the cord ends alligator plug marking heads and grounds clean If corrosion appears use a light abrasive such as an emery cloth to clean it off B To prevent corrosio...

Страница 7: ...DE monopad for best results G Place the stencil over the pad with the reading face down as if to read the information from the bottom of the fixture Slide the O ring over the stencil pad and top plate until it snaps into the machined groove H Connect the hand ground flat bottom or knife edge to the ground jack of your power unit I Place the substrate surface to be marked on the stencil in front of...

Отзывы: