background image

Talisman III Dynamic Loop Amplifier Systems (TAL/DLS1/3 & TAL/DLS5/3)

Publication Code TAL-DLS-3_TIG Issue 3

Page 7

4.

CHECK-LIST FOR SYSTEM DESIGN USING TAL/DLS

Refer also to setting up procedure on following pages

4.1

Before starting you will need the following:

a)  Tape measure (at least 10m long).

b)  Magnetic field strength meter.

c)  AFILS receiver (headphones and hearing aid recommended).

d)  Tape of continuous speech and tape-player, or a sympathetic assistant with a microphone.

4.2

Using the receiver(s) and field strength meter check the area to be covered for background magnetic noise.
Dimmers, power cabling, motors, etc., which can radiate powerful magnetic noise must be switched off
during this test. No standard currently exists but we recommend that  the noise should be at least 26dB
below 0.1A/m and that the character of the noise is not objectionable (buzzes can sound worse than pure
hum).

4.3

Together with the customer decide on the most appropriate positioning for the wire loop and take the
dimensions so that an ‘ideal’ shape can be approximated (square or rectangle, etc.). Note the width
(shortest side of the loop), and calculate in metres the aspect ratio by dividing the width by the length.

4.4

Using the graph, find the width (shortest side) of the loop and move vertically up the graph until an
intersection is made with the appropriate ‘aspect ratio’ line.

4.5

The intersection of the loop width and ‘aspect’ ratio also determine the conductor area of the cable to be
used, taking into account both the current-carrying capacity and cable resistance.

The current demanded by this size of loop can be read – off the vertical axis. If the current indicated
is in excess of 9 Amps then separate loops should be employed, driven by separate amplifiers.

4.6

Temporarily install the loop as close as possible to its final position  and test with the taped speech or
microphone and TAL DLS amplifier to confirm design parameters.

Hidden metalwork, etc., may cause reductions in field strength which can be compensated by
adjusting the master control during this test. In extreme cases the installation may prove totally
unsuitable for loop use and an alternative technology offered to the customer (e.g. Infra-Red
systems).

The frequency response should also be checked, losses of high frequencies may be recovered by
the use of the TAL DLS ‘Response’ control.

4.7

Assuming satisfactory test results, permanently install the loop wiring (not in metal conduit or trunking),
signal cabling (which should be routed as far as possible from the loop wire) and a.c. power supply. The
amplifier generates heat and must be located in a position with adequate ventilation.

4.8

Set all ‘input’ front panel gain controls to maximum, the ‘master’ control and ‘response’ control to mid
positions. Set the ‘response’ switch (located on the rear panel) to the required position – 5KHz for hearing-
aid use, 10KHz for other uses.

4.9

Depending on the use of the system, the AGC is set-up in two alternative ways:

4.9.1

AGC and limiting (for hearing aid use). Select the AGC mode by setting the ‘AGC’ switch (located
on the rear panel) to ON.

4.9.2

Limiting only (for non hearing aid use). Select the limiter only mode by setting the ‘AGC’ switch to
OFF (the switch is located on the rear panel).

4.10

The master control should now be adjusted to give the required current drive to the loop, indicated by the
bargraph display on the front panel. The field strength must be checked and the amplifier master control
adjusted if necessary.

4.11

Check the field strength over the entire area to be covered, note any areas of poor coverage and ensure
that hearing aid users are notified of such areas.

Содержание Talisman TAL/DLS1/3

Страница 1: ... FEDERAL SIGNAL LIMITED PUBLICATION OF THIS INFORMATION DOES NOT IMPLY ANY AUTHORITY OR LICENCE FOR THE UTILISATION IN ANY MANNER IN ANY COUNTRY OR ANY PATENTED OR REGISTERED DESIGN FEATURES MECHANICAL ELECTRICAL OR AESTHETIC MILLBANK ELECTRONICS is part of FEDERAL SIGNAL LTD Signal House Charter Way Hurdsfield Industrial Estate Macclesfield Cheshire SK10 2NF England TEL 44 0 1625 66 66 00 FAX 44 ...

Страница 2: ...rature Failure to use the modular products in the manner described will invalidate the EC Compliance Our products meet the appropriate British and International standards A product Declaration of Conformity Statement is available for each of the product ranges available on request This covers both the EMC and Low Voltage Directives UNPACKING While all Millbank equipment is carefully packed to prev...

Страница 3: ...an earth is dangerous and may cause high levels of audible hum from the loudspeaker outputs 1 1 4 Avoid siting the equipment in locations exposed to direct sunlight near heaters or other heat sources Avoid locations with high humidity or dust levels Do not obstruct the ventilation slots in the amplifier case and if the amplifier is rack mounted ensure that a 1U ventilation panel is fitted above th...

Страница 4: ... of the internal pick up coils normally fitted to hearing aids Now with a suitably installed AFILS the hearing impaired can appreciate and enjoy everything that those with normal hearing do and as mentioned above the same type of system can be used to provide paging life safety communication in very noisy areas secret paging for security staff disturbance free audio for spoken commentary systems o...

Страница 5: ...nce to match exact requirements of the listener 3 4 Switchable Automatic Gain Control Compensates for differences between signal inputs microphones for example especially important for hearing aid users 3 5 Fast Acting Compression Circuitry Controls signal peaks without audible distortion and prevents generation of interference within the amplifier 3 6 L E D Display for optimum input levels and lo...

Страница 6: ...loop The graph corresponds to DLS use with the AGC switched on Thus the maximum r m s current in the loop is limited in the event of fault conditions such as feedback between loop and microphone If the amplifier is to be used with the AGC switched off a longer continuous current could be produced under fault conditions and therefore care should be taken to allow for this in selecting conductor typ...

Страница 7: ...loyed driven by separate amplifiers 4 6 Temporarily install the loop as close as possible to its final position and test with the taped speech or microphone and TAL DLS amplifier to confirm design parameters Hidden metalwork etc may cause reductions in field strength which can be compensated by adjusting the master control during this test In extreme cases the installation may prove totally unsuit...

Страница 8: ...t 5 seconds 4 13 As a final check the response control should be adjusted if necessary to achieve optimum frequency response 4 14 Set all unused input control to minimum 4 15 The notice supplied with the equipment informing potential hearing aid users that the system is installed should be clearly displayed 4 16 Before leaving the installation it is most important that the owner and users of the s...

Страница 9: ...c 1 10kHz Agc 5kHz Limiter Response Mode England SK10 2NF Ser No TAL DLS5 Dynamic Loop Amplifier System Hurdsfield Industrial Estate Macclesfield Cheshire Federal Signal Ltd Signal House 5 2 TAL DLS 5 3 1 Microphone Input Level Controls 2 Auxiliary Input Level Controls 3 Tone Control 4 Master Level Control 5 Loop Integrity Indicator 6 Loop Current Indicator 7 Input Level AGC Indicator 8 Input Leve...

Страница 10: ... microphone inputs are balanced with 200µV 200 sensitivity Signal is connected to pin 1 and the screen to pin 2 Wiring Instructions for Microphone Input 1 Wiring Instructions for Microphone Inputs 2 and 3 6 1 3 Auxiliary Up to two auxiliary input signals can be used these can be from signal sources such as Cassette Radio or CD players Two sensitivity levels are provided at 300mV low and 50mV high ...

Страница 11: ...put level controls located on the front panel In the limiter mode the input level should be set such that the limiter LED only illuminates during signal peaks For hearing impaired applications Set the response switch to 5KHz the mode switch to AGC The AGC input level LED should illuminate only whilst signal is passing through the equipment For silent paging applications Set the response switch to ...

Страница 12: ...p The guarantee does not extend to damage caused by improper installation improper storage misuse or operation outside stipulated conditions Our warranty covers only goods returned to our premises for either repair or replacement as deemed appropriate by Federal Signal Ltd In order to expedite the process Contact your supplier and quote the model and serial number of your equipment Should you requ...

Страница 13: ...irst Issue Mar 00 02 Updated to include new standard clauses and company details May 01 03 Updates section 6 to include wiring details and referral to additional programming features Dec 01 03 Jumper setting investigated and recorded See Customer Services Department Dec 01 Referenced Documentation Title Publication Code Referenced Tools Description Part Number ...

Отзывы: