After you have converted the cooktop to another gas type, make sure you have placed a label
containing that information on the appliance.
Adjustment of the reduced valve flow
TABLE2:
How to convert gas source
Burners
Flame
Converting the
cooktop from LPG
to natural gas
Converting the
Cooktop from natural
Gas to LPG
Regular burners
Full flame
Replace the burner
Nozzle according
to the guidelines in
table 1
Replace the burner
Nozzle according
to the guidelines in
table 1
Saving flame
Loosen the adjustment
Spindle (
see fig.7 below
)
And adjust the flame
Loosen the adjustment
Spindle (
see fig.7 below
)
And adjust the flame
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving flame position.
Remove the knob, and adjust the flame with a tiny screwdriver (see fig.7 below).
Fig.7
Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the knob into the saving
setting. The flame should not extinguish nor move to the nozzle. If it goes off or moves over to the nozzle, re-adjust
the valves.
Note.
It is up to the user to request converting the appliance to another gas type if so required by the local conditions at a
licensed gas fitter/ service.
Flame selection
At the burners adjusted correctly, the flames should be light blue, and the inner cone should be clearly visible. The
size of flame depends on the position of the related burner control knob.