IR Remote

: -

 

All the new switcher has IR sensor on the front panel.

IR-8 Remote is provided with the equipment to select the channels.
On   the   rear   side   one   EP   Connector   (IR.EXT,)   is   provided   for
connecting IR sensor cable which can be extended upto 30Mts.

SCANNING MODE  

For   scanning   mode,   keep  slide-switch  at   the   rear   panel   in   scan
position before powering ON the unit. Set the DIP SWITCH for the
Channels   to   be   Scanned   (see   the   note   below).
PWR ON the unit & check SCAN LED. Scanning time for each
channel is 20 seconds (default).
To   stop   the   scanning   press   any   channel   key   from   the   remote
keypad. To start scanning press scan Key (Mute) from the remote
keypad. Front Panel has LED to indicate Scan mode status.

Note

: The I/P channels will be scanned depending on the DIP Switch

setting (not for 201HDMI & 202HDMI) eg. for scanning 1, 3 & 5,
Keep the DIP Switch 1,3 & 5 ON. Rest all OFF.

The Scan time can also be set using DIP Switch (not for 201HDMI &
202HDMI).

1) PWR OFF the unit.
2) Set the DIP Switch as per Table 1.
3) Press key No.1 from the front panel.
4) Keeping the key no.1 pressed PWR ON the unit
5) If the timer is set properly Scan LED will start blinking.
6) PWR OFF the unit.
7) Set the DIP Switch for the channels to be scanned.
8) PWR ON the unit (with scan mode ON).
9) The I/Ps will start scanning depending on the time set.

Содержание ML 202 HDMI

Страница 1: ...OPERATING MANUAL FOR HDMI SWITCHER NEW Milestone Electronics Pvt Ltd...

Страница 2: ...802 HDMI 8 HDMI Inputs with 2 HDMI outputs Features INSTALLATION Easy to install plug and play kind HDTV Compatible Can work with DVI inputs outputs Uses Equalization re clocking technology SHARING 2...

Страница 3: ...Yes Yes Yes Yes Yes Yes IR EXTENDER CONNECTOR FOR REMOTE SENSOR EP 1 EP 1 EP 1 EP 1 EP 1 EP 1 RS 232 INTERFACE D9F 1 D9F 1 D9F 1 D9F 1 D9F 1 D9F 1 OPERATING DISTANCE FOR REMOTE KEYPAD 30 M 30 M 30 M 3...

Страница 4: ...or such as IR Remote RF Remote etc The connector diagram for D9 male connector is as follows D 9 MALE 1 Pin No CHANNELS 1 CH1 2 CH2 3 CH3 4 CH4 5 CH5 6 CH6 7 CH7 8 CH8 9 GRD Note 1 To select any chann...

Страница 5: ...used for selecting the channels are CHANNEL DECIMAL ASCI I CHANNEL1 1 31 21 CHANNEL 2 2 32 21 CHANNEL 3 3 33 21 CHANNEL 4 4 34 21 CHANNEL 5 5 34 21 CHANNEL 6 6 34 21 CHANNEL 7 7 34 21 CHANNEL 8 8 38...

Страница 6: ...y channel key from the remote keypad To start scanning press scan Key Mute from the remote keypad Front Panel has LED to indicate Scan mode status Note The I P channels will be scanned depending on th...

Страница 7: ...N 0 OFF 1 2 3 4 TIME 0 0 0 0 20 Secs 1 0 0 0 10 Secs 0 1 0 0 20 Secs 1 1 0 0 30 Secs 0 0 1 0 40 Secs 1 0 1 0 50 Secs 0 1 1 0 60 Secs 1 1 1 0 70 Secs 0 0 0 1 80 Secs 1 0 0 1 90 Secs 0 1 1 1 140 Secs 1...

Страница 8: ......

Отзывы: