Milesight LoRaWAN UC511 Скачать руководство пользователя страница 7

7

DIP Switch:

Interface

DIP Switch

Solenoid

Interface

12V: 1 on 2 off 3 off

9V: 1 off 2 on 3 off
5V: 1 off 2 off 3 on

Note:

1) The DIP switch is set to 12VDC by default.
2) The DIP switch does not support setting two solenoid interfaces as different voltage types.

Power Button:

Function

Action

LED Indication

Turn On

Press and hold the button for more than 3s.

Off

On

Turn Off

Press and hold the button for more than 3s.

On

Off

Reset

Press and hold the button for more than 10s.

Blinks.

Check

On/Off Status

Quickly press the power button.

Light On:

Device is on.

Light Off: Device is off.

2.4 Dimensions (mm)

3. Operation Guide

3.1 Log in the ToolBox

UC51x series can be monitored and configured via ToolBox App or ToolBox software. Please
select one of them to complete configuration.

3.1.1 NFC Configuration

1. Download and install “Milesight ToolBox” App from Google Play or Apple App Store.

Содержание LoRaWAN UC511

Страница 1: ...LoRaWAN Solenoid Valve Controller UC51x Series User Guide...

Страница 2: ...the reverse or wrong model The device must never be subjected to shocks or impacts Declaration of Conformity UC51x series is in conformity with the essential requirements and other relevant provisions...

Страница 3: ...sion Nov 26 2021 V 1 1 Description Update March 10 2021 V 2 0 Update based on 2 0 hardware June 15 2022 V 2 1 1 Add internal interface description 2 UC511 supports Class C to B mode 3 GPIO supports se...

Страница 4: ...3 1 Log in the ToolBox 7 3 1 1 NFC Configuration 7 3 1 2 USB Configuration 8 3 2 Solenoid Valve Control 9 3 3 LoRaWAN Settings 10 3 4 Solenoid Settings 13 3 5 Schedule Settings 15 3 6 Maintenance 16...

Страница 5: ...dust under harsh environments 1 2 Features Compatible with standard DC latching solenoids OPEN CLOSE control by mobile App locally or commands remotely Two GPIO interfaces for flow monitoring or valve...

Страница 6: ...terface 1 2 Pin Description 1 DC OUT1 of Solenoid Valve 2 DC OUT2 of Solenoid Valve 3 GND 4 INSERT BOOT1 5 GND 6 GPIO Interface 2 3 Internal Interfaces 1 PIN3 and PIN4 do not need to connect see Solen...

Страница 7: ...for more than 3s Off On Turn Off Press and hold the button for more than 3s On Off Reset Press and hold the button for more than 10s Blinks Check On Off Status Quickly press the power button Light On...

Страница 8: ...first configuration Default password is 123456 Note 1 Ensure the location of smartphone NFC area and it s recommended to take off phone case 2 If the smartphone fails to read write configurations via...

Страница 9: ...r Off to turn on off device and change other settings 3 2 Solenoid Valve Control Solenoid valve can be controlled by ToolBox App or ToolBox software locally Via ToolBox Software Click Open or Close bu...

Страница 10: ...enoid valves 3 3 LoRaWAN Settings LoRaWAN settings is used for configuring the transmission parameters in LoRaWAN network Basic LoRaWAN Settings Go to LoRaWAN Settings Basic of ToolBox software or Set...

Страница 11: ...evAddr for ABP mode default is the 5th to 12th digits of SN Network Session Key Nwkskey for ABP mode default is 5572404C696E6B4C6F52613230313823 Application Session Key Appskey for ABP mode default is...

Страница 12: ...se Milesight IoT cloud to manage devices 4 Only OTAA mode supports rejoin mode LoRaWAN Frequency Settings Go to LoRaWAN Settings Channel of ToolBox software or Setting LoRaWAN Settings of ToolBox APP...

Страница 13: ...915 3 4 Solenoid Settings Go to Device Settings Basic of ToolBox software or Setting General Settings of ToolBox App to change the reporting configurations Parameters Description Reporting Interval Re...

Страница 14: ...C Class C to B are available UC512 Class A and Class B are available Note for Class B mode if the device does not receive beacons for more than 30 minutes it will switch to Class A mode automatically...

Страница 15: ...ntrol the solenoid to open or close the valve during the plan Start Time End Time Set the time range to execute this plan Water Volume Pulses Set the amount of water flow through the valve during this...

Страница 16: ...fter joining the network the network server will assign the time to the device You can also manually sync the time via ToolBox or downlink commands 2 When the device has multiple schedule plan setting...

Страница 17: ...rt configuration backup for easy and quick device configuration in bulk Backup is allowed only for devices with the same model and LoRa frequency band Note that the backup file will not save schedule...

Страница 18: ...ate file 2 Select this template and attach to another device to write configuration 3 6 3 Reset to Factory Default Please select one of following methods to reset device Via Hardware Open the case of...

Страница 19: ...all mounting or pole mounting Before installation make sure you have the mounting bracket wall or pole mounting kits and other required tools Wall Mounting 1 Fix the wall plugs into the wall then fix...

Страница 20: ...ixing screw 5 Milesight IoT Cloud Management UC51x series can be managed by Milesight IoT Cloud platform Milesight IoT cloud is a comprehensive platform that provides multiple services including devic...

Страница 21: ...nd click New Devices Fill in the SN of UC51x and select associated gateway 3 Click and go to Basic Settings to change class type the same as device settings Besides configure the unit of per pulse if...

Страница 22: ...tomize the name and thresholds 5 2 Solenoid Valve Control Solenoid valve can be controlled by Milesight IoT cloud webpage or App 1 Click to open the solenoid valve and configure the duration Note that...

Страница 23: ...g mode of UC51x is LoRaWAN Class A control commands will delay until the time icon disappear 2 Go to Triggers page to add actions to trigger the solenoid valve to open for a period of time or a specif...

Страница 24: ...Device Payload UC51x Series use the standard Milesight IoT payload format based on IPSO Please refer to the UC51x Series Communication Protocol for decoders of Milesight IoT products please click here...

Отзывы: