14
Solenoid Valve
Wiring Switch
After this parameter is enabled, when users connect the solenoid cable to
any solenoid interface, the device will turn on automatically.
GPIO1/2
Acquisition Type
Select Digital Input or Pulse Counter.
Digital input: detect the state of valve; if any DI changes state, it will
upload packet to cover the valve status.
Pulse counter: connect water meter to measure the flow.
Data Reporting
Select the contents to report to network server.
All: Report all interface status;
Valve 1 & Water Meter 1: Report the status of the Valve 1 interface and
data of GPIO1;
Valve 2 & Water Meter 2: Report the status of the Valve 2 interface and
data of GPIO2.
Device Return to
Power Supply State
If the device loses power and return to power supply, the device will be on
or off according to this parameter.
Class Type
Working mode of LoRaWAN
®
device.
UC511: Class A, Class B and Class C, Class C to B are available;
UC512: Class A and Class B are available.
Note:
for Class B mode, if the device does not receive beacons for more
than 30 minutes, it will switch to Class A mode automatically; for Class C
to B mode, if the device does not receive beacons for more than 30
minutes, it will switch to Class C mode automatically.
Response Time
When the device works under Class A mode, it only receives control
commands every reporting interval comes. In order to shorten the delay
time of control, the device will send blank package to allow to receive the
control commands every Response Time interval.
Note:
The shorter the response time, the shorter the battery life.
Ping Slot
Periodicity
When the device works under Class B or Class C to B mode, set the
interval to open the reception window.
Change Password
Change the password for ToolBox App or software to read/write this
device.
Note:
1) When device connects to network server of Milesight gateway, the blank package will take up
the frame count but not show on the package list.
2) Reboot or re-join will not affect the counting.