Milesight EM310-UDL Скачать руководство пользователя страница 13

13

4. Installation

1. Fix the wall plugs into the wall, then fix the device to the wall plugs with screws.
2. Cover the screws with screw caps.

Installation location:

Ensure the location of device is within the communication range of LoRaWAN

®

gateway and

keep it away from metal objects.

Device must sit in a horizontal position on top of the object so that it has a clear path to the
object.

Place device in where it is far away from the side-wall more than

30 cm

and without internal

obstructions that block the ultrasonic signal. If the device has to install on the side wall,
please ensure the ultrasonic sensor direction point away from the wall.

5. Milesight IoT Cloud Management

EM310-UDL can be managed by Milesight IoT Cloud platform. Milesight IoT cloud is a
comprehensive platform that provides multiple services including device remote management
and data visualization with the easiest operation procedures. Please register a Milesight IoT
Cloud account before operating following steps.

1. Ensure Milesight LoRaWAN

®

gateway is online in Milesight IoT Cloud. For more info about

connecting gateway to cloud please refer to gateway’s user guide.

Содержание EM310-UDL

Страница 1: ...Milesight IoT Ultrasonic Distance Sensor EM310 UDL User Guide...

Страница 2: ...ever be subjected to shocks or impacts Declaration of Conformity EM310 UDL is in conformity with the essential requirements and other relevant provisions of the CE FCC and RoHS Copyright 2011 2021 Mil...

Страница 3: ...ide 5 3 1 NFC Configuration 5 3 2 LoRaWAN Settings 6 3 3 Basic Settings 9 3 4 Advanced Settings 10 3 4 1 Calibration Settings 10 3 4 2 Threshold Settings 10 3 5 Maintenance 11 3 5 1 Upgrade 11 3 5 2 B...

Страница 4: ...LoRaWAN protocol LoRaWAN enables encrypted radio transmissions over long distance while consuming very little power The user can obtain sensor data and view the trend of data change through Milesight...

Страница 5: ...seconds Off On Switch Off Press and hold the button for more than 3 seconds On Off Reset Press and hold the button for more than 10 seconds Quickly Blinks Check On Off Status Quickly press the power b...

Страница 6: ...utton to write all your settings to the device Note 1 Ensure the location of smartphone NFC area and it s recommended to take off phone case 2 If the smartphone fails to read write configurations via...

Страница 7: ...for ABP mode default is 5572404C696E6B4C6F52613230313823 Spread Factor If ADR is disabled the device will send data via this spread factor Confirmed Mode If the device does not receive ACK packet fro...

Страница 8: ...ngs of ToolBox App to select supported frequency and select channels to send uplinks Make sure the channels match the LoRaWAN gateway If frequency is one of CN470 AU915 US915 you can enter the index o...

Страница 9: ...the reporting interval etc Parameters Description Reporting Interval Reporting interval of transmitting data to network server Default 10 mins Range 1 1080 mins Tilt Distance Switch When detected the...

Страница 10: ...can define either outlier range or value When the device distance value exceeds the outlier range or value comparing to last value the device will measure the distance again 3 4 2 Threshold Settings...

Страница 11: ...version ToolBox supports the upgrade feature 3 5 2 Backup EM310 UDL support configuration backup for easy and quick device configuration in bulk Backup is allowed only for devices with the same model...

Страница 12: ...dit the configurations 3 5 3 Reset to Factory Default Please select one of following methods to reset device Via Hardware Hold on power button internal for more than 10s Via ToolBox App Go to Device M...

Страница 13: ...nternal obstructions that block the ultrasonic signal If the device has to install on the side wall please ensure the ultrasonic sensor direction point away from the wall 5 Milesight IoT Cloud Managem...

Страница 14: ...lesight IoT Cloud you can check the data via webpage or mobile App and create dashboard for it 6 Device Payload All data are based on following format HEX Channel1 Type1 Data1 Channel2 Type2 Data2 Cha...

Страница 15: ...3b31056670013 ff090100 ff0a0100 ff0f00 Channel Type Value Channel Type Value ff 0b Power On ff Reserved ff 01 Protocol Version 01 V1 Channel Type Value Channel Type Value ff 16 Device SN 6713b31056 67...

Страница 16: ...pplication port is 85 by default Example Set reporting interval as 20 minutes END Channel Type Value 04 00 Device Position 00 Normal Channel Type Description ff 03 Set Reporting Interval 2 Bytes unit...