16
After the connection between the conversion system and PC is finished,
turn on the PC or terminal and
run a terminal emulation program or
Hyper Terminal
to match the following default characteristics of the
console port:
Baud Rate: 9600 bps
Data Bits: 8
Stop Bit: 1
Parity: none
Flow control: None
Figure 4-2. The setting of communication parameters
In order to telnet from a directly connected PC to the Device, the IP
address of the PC must be in the same class as the Device. The default
IP address of the Device is 192.168.1.77, with a subnet mask of
255.255.255.0. A recommendation is to set the PC IP address to
192.168.1.156 with a subnet of 255.255.255.0. Then using a telnet
program on your PC telnet to address 192.168.1.77. The default user
name is
root
with the default password of
root
.
After you have entered the parameter settings, press the “
Enter
“ Key and
the Main Menu of console management appears.