background image

User’s Guide

MIL-FT240TX
10/100 Fault-Tolerant Stand-Alone
Transceiver

•  10/100 Base-T(x) to 10/100 Base-T(x) 

•  Ethernet/Fast Ethernet

The MIL-FT240TX is a fault-tolerant

transceiver, providing redundant paths for fast Ethernet devices. It has three ports: main,
primary, and backup. Typically, the main port connects to a critical 10/100 fast Ethernet
device. The primary port and the backup port connect to two different switch ports or two
different ports on separate switches. When the unit powers up, it checks the primary port
for a link signal; if the signal is present, the main and primary ports will connect and the
signal from the backup port is disabled. Any device connected to the backup port will not
detect a signal at this time. However, if the device does not detect a signal on the primary
port, then the main port and backup port connect. 

Product features  . . . . . . . . . . . . . . . .2
Installation  . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .5
Cable Specifications  . . . . . . . . . . . . .6
Troubleshooting  . . . . . . . . . . . . . . . .7
Technical Specifications  . . . . . . . . . .9
Contact Us  . . . . . . . . . . . . . . . . . . .10
Compliance Information . . . . . . . . .11

*Typical maximum cable distance. Actual distance is dependent upon the physical
characteristics of th network.

Part Number

Port One - Copper
10/100Base-T(x)

Port Two Copper
10/100Base-T(x)

Port Three - Copper
10/100Base-T(x)

MIL-FT240TX

RJ-45 100 M

(328 ft*)

RJ-45 100 M

(328 ft*)

RJ-45 100 M

(328 ft*)

Содержание MIL-FT240TX

Страница 1: ...the signal is present the main and primary ports will connect and the signal from the backup port is disabled Any device connected to the backup port will not detect a signal at this time However if...

Страница 2: ...ines the maximum length of cable permitted by calculating the round trip delay in bit times BT of a particular collision domain If the result is less than or equal to 512 BT the path is good AutoCross...

Страница 3: ...cording to network conditions RJ 45 Port Transceiver RJ 45 Port Switch Workstation etc 5 MIL FT240TX Installation continued Connecting power to the media converter AC DC 1 Connect the barrel connector...

Страница 4: ...Technical Support 1 800 466 4526 Press 2 International 1 408 744 2751 Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3...

Страница 5: ...e 0 10 000 feet Warranty 5 year limited Troubleshooting continued 6 Is there an RJ 45 cable inserted into the backup port on the transceiver NO a Insert the RJ 45 cable into the transceiver backup por...

Страница 6: ...likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Clas...

Страница 7: ...of their respective owners Copyright restrictions 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or me...

Отзывы: