Install Guide

Model: MIL-03F

2

 

I n t ro d u c t i o n

 

The MIL-03F is an Ethernet, single-mode fiber transceiver that comes equipped 
with diagnostic LEDs, an AUI male connector, and either an SC- or ST-type fiber 
connector.

 

I n s t a l l a t i o n

 

1. Connect the fiber cables: Attach the fiber cables from the fiber network cabling 

to the ST-type connectors on the MIL-03F.

2. Attach the 15-pin AUI connector from the MIL-03F to the DB-15 connector on 

the device you wish to connect to.

3. Tighten the latch screws to secure the unit.

4. Restart the computer. The 

 

PWR

 

 LED illuminates.

 

Note:

 

If the 

 

PWR

 

 LED did not illuminate, reinstall the MIL-03F. If it still does not illuminate, contact 

our technical support department.

 

C o n fi g u r a t i o n

 

The MIL-03F comes with configurable options, which include a 2-position DIP 
switch and a 3-pin jumper. The DIP switch is located on left-side of MIL-03F 
(while facing the device), and the jumper is located inside the device. To open the 
MIL-03F to access the 3-pin jumper:

1. For device's with ST-type connectors, unscrew the two hex nuts that secure the 

ST-type connectors.

2. Slide the top-half of the enclosure off, over the fiber connector.

The jumper is located on right-hand side of the device (Figure 1).  

 

D I P   S w i t ch

 

The Link Sentry feature on the MIL-03F is configured through the 2-position DIP 
switch located on the side of the transceiver. Use a mechanical pencil to adjust the 
DIP switches. 

LinkSentry transmits link pulses only if the receive side of the link is seen. This 
allows fault-tolerant transceivers and hubs to detect faulty cables or bad 
equipment. Settings for the DIP switch includes:

 

Table 1: DIP Switch Settings

 

Up (off)

Down (on)

 

Switch 1

LinkSentry disabled (Default)

LinkSentry enabled

Switch 2

SQE disabled (Default)

SQE enabled