background image

LEDs 

Ethernet LED is on when the board is powered. It is the first LED from the bottom.   

There are five LEDs which show wireless signal strength:  

1 ‐ on, if wireless client is connected to AP (usually >= ‐89dBm)  

2 ‐ on, if signal strength >= ‐82dBm (bad signal) 

3 ‐ on, if signal strength >= ‐75dBm  

4 ‐ on, if signal strength >= ‐68dBm  

5 ‐ on, if signal strength >= ‐61dBm  (good signal = all LEDs on) 

 

It is possible to disable this function (turn all these LEDs off or re‐assign them) via software configuration.  

User's Guide 

Mounting 

The Groove is to be mounted 

vertically

, so that the Ethernet cable points 

downwards

.  

If you wish to tighten the Groove to a pole, you can do it with the provided mounting loops. The Groove comes 

bundled with two mounting loops ‐ guide the loops around the Groove though the provided edge markings, 

and around the pole where it will be mounted. You should avoid connecting a loose Ethernet cable to the 

Ethernet port, secure the cable to a wall or the pole, so that the cable weight is not pulling the port. It is 

recommended to secure the Ethernet cable less than 2m from the Groove device. This is to ensure that the 

cable doesn't damage the port by it's weight, or doesn't fall out. 

First use 

The device is assembled and ready for deployment. You must mount the antenna on the built‐in N‐male 

connector before turning on the device via PoE! 

1.

 

Mount an antenna on the built in N connector. Any antenna can be used, which works in the 

frequencies supported by the chosen Groove model 

2.

 

Plug the supplied PSU into a power socket, and connect it to the supplied PoE injector 

3.

 

Connect the “DATA” end of the injector to a switch or any other device, and the other end (which says 

“DATA+POWER”) to an Ethernet cable leading to the Groove device 

4.

 

Open 

192.168.88.1

 in your web browser to start Quickset and configure the Groove. You might need 

to adjust your PC IP address to connect to this IP. For advanced configuration guides, see: 

http://wiki.mikrotik.com/wiki/Category:Manual 

 

In case IP connection is not available, 

Winbox

 can be used to connect to the MAC address of the 

device. More information here: 

http://wiki.mikrotik.com/wiki/First_time_startup

 

 

Grounding 

It is recommend using a FTP (foil screened twisted pair) cable – in this case, one end of the cable would be 

plugged into the SXT, the other end of the cable will be connected to the buildings grounding installation. If 

possible, also connect a grounding wire to the provided grounding connection behind the SXT case door.  

Powering 

Power over Ethernet (PoE) on the Ethernet port: 8‐30V DC (12‐28 V suggested) non‐standard PoE powering 

support. 24V PSU is supplied with the device 

Содержание Groove 2Hn

Страница 1: ...s to MikroTik you must perform the following RMA Return Merchandise Authorization procedure Follow the instructions below to save time efforts avoid costs and improve the speed of the RMA process 1 If you have purchased your product from a MikroTik Reseller please contact the Reseller company regarding all warranty and repair issues the following instructions apply ONLY if you purchased your equip...

Страница 2: ...EDS 4 USER S GUIDE 4 MOUNTING 4 FIRST USE 4 GROUNDING 4 POWERING 4 EXPANSION SLOTS AND PORTS 5 BUTTONS AND JUMPERS 5 BOOTING OPTIONS 5 Onboard NAND Storage Device 5 Booting from network 5 Operating System Support 6 ROUTEROS FUNCTIONS 6 HEALTH MONITOR 6 FIRMWARE INFORMATION 6 FIRMWARE SETTINGS 6 APPENDIX 7 ETHERNET CABLES 7 SYSTEM BOARD VIEW AND LAYOUT 7 ...

Страница 3: ...ointing down 177x44x44mm 193g Must be mounted with ethernet pointing down 177x44x44mm 193g Must be mounted with ethernet pointing down 177x44x44mm 193g Must be mounted with ethernet pointing down Operational Temperature 30C to 70C 30C to 70C 30C to 70C 30C to 70C Power consumption Up to 0 19A at 24V 4 56W Up to 0 19A at 24V 4 56W Up to 0 19A at 24V 4 56W Up to 0 19A at 24V 4 56W RouterOS V5 Licens...

Страница 4: ...led and ready for deployment You must mount the antenna on the built in N male connector before turning on the device via PoE 1 Mount an antenna on the built in N connector Any antenna can be used which works in the frequencies supported by the chosen Groove model 2 Plug the supplied PSU into a power socket and connect it to the supplied PoE injector 3 Connect the DATA end of the injector to a swi...

Страница 5: ... Netinstall servers Booting options In case you wish to boot the device from network for example to use MikroTik Netinstall hold the RESET button of the device when starting it until the LED light turns off and Groove will start to look for Netinstall servers Onboard NAND Storage Device The RouterBOARD may be started from the onboard NAND storage chip As there is no partition table on the device t...

Страница 6: ... RouterBOOT menu through the serial console Health monitor This menu shows the current voltage and temperature status There are two temperature sensors on the device admin MikroTik system health print voltage 12 4V temperature 40C admin MikroTik Firmware information This menu displays RouterBOARD model number serial number the current boot loader version and the version available in the current so...

Страница 7: ...or Crossover cable MDI X EIA TIA568B 1 Green TX Data Data A 1 3 2 Green White TX Data Data A 2 6 3 Orange RX Data Data B 3 1 4 Blue Data C 4 4 5 Blue White Data C 5 5 6 Orange White RX Data Data B 6 2 7 Brown Data D 7 7 8 Brown White Data D 8 8 System Board View and Layout You can download the board dimensions and case design files PDF and DXF from www routerboard com ...

Отзывы: