1. Safety 

Instructions 

 

CAUTION! Please read the following 
information carefully before using the unit and its 
supplementary equipment! 
 
This unit was constructed and checked 
according to the safety regulations for electronic 
measuring devices, and was delivered securely. 
This User Manual contains information and 
warning notices that should be heeded by the 
user. 
 
The unit is a light microscope, drafted according 
to the newest scientific and technical knowledge 
for the visual, micro photographic and video-
technical investigation of microscopic objects. 
The unit should only be used for the designed 
purpose. All other uses (also the insertion of 
single components which were not designed by 
the manufacturer) constitute a misuse of the 
product. We are not liable for any damages 
caused by this misuse.  
 
This unit is not meant for unattended continuous 
operation. 
 
The microscope does not have any special 
safeguards against samples with caustic toxic, 
radioactive or other hazardous materials. The 
allowed sample amount may not be exceeded. 
 
The unit may only be operated on the voltages 
indicated on the unit. Please heed the 
instructions in the user manual! We are not liable 
for any damages caused by the disregard of 
these instructions. 
 
If the unit is connected to voltage, contact 
clamps can lead to dangerous voltages and 
opening the coverings or removing parts can 
uncover a piece under a dangerous voltage. 
The unit must be disconnected from power 
before it can be opened for

 

adjustments, 

replacements, servicing or repairs. 

Existing ventilation slits should not be obstructed. 
This also applies for ventilation slits on the 
bottom of the unit. No tools, loose objects or 
liquids should

 

enter the unit through ventilation 

slits or other openings in the unit.  
 
Only fuses with the required nominal current may 
be used as substitutes for the prescribed use. It is 
prohibited to use makeshift fuses or short-circuit 
the fuse support. 
 
If safety is endangered , the unit must be 
removed from use and secured against 
unattended operation. The unit should then be 
sent to the production factory or a competent 
service technician. 
 
Before switching on the unit, set the controller for 
the illumination intensity to the left catch in order 
to prevent blinding. 
 
1.1.  

Characteristics and Application 

 
The microscope RMA 5 is equipped with high 
quality optics, and excels due to its high optical 
performance.   
 
The following additional devices are available:  
evaluation of investigations over Photo-/TV 
adapter and digital cameras, Polarization 
equipment, measuring software...  
 
Different interchangeable objectives and 
eyepieces, which can be changed easily by a 
revolver (quadruple), make an extension area in 
an interval of 50x ... 640x possible (standard 
configuration). 
 
 
 
 
 
 
 
 
 

Содержание RMA 5

Страница 1: ...Polarization Microscope RMA 5 pol Technical Incident Light Microscope RMA 5 User Guide...

Страница 2: ......

Страница 3: ...tor 12 2 5 General Operating Instructions 13 2 5 1 Vertical adjustment of the Microscope 13 2 5 2 Optimising the illumination 13 2 5 3 Changing the tubes 13 2 5 4 Changing the objectives 13 2 5 5 Chan...

Страница 4: ...1 TV Transfer over Photo TV tube 19 8 1 1 TV Adapter 1 0x 19 8 1 2 TV Adapter 0 3x 0 4x 0 4xWF 0 63x 1 6x 19 9 Illumination 9 1 3W LED transmitted light 20 9 2 Oblique incident light dark field 20 10...

Страница 5: ...age contact clamps can lead to dangerous voltages and opening the coverings or removing parts can uncover a piece under a dangerous voltage The unit must be disconnected from power before it can be op...

Страница 6: ...ansmitted light illumination Koehler principle All electronic parts for the illumination are integrated into the microscope base There is a control for adjusting the illumination in front and on the s...

Страница 7: ...n Koehler principle with filter holder field diaphragm and aperture diaphragm Total magnification Vt Vobj x Veyep 50x 500x Object field mm 4 0 0 4 Adjustable range of coarse drive 20 mm Max High of ob...

Страница 8: ...age carrier with rotary stage The objects will be illuminated by a 3W LED incident light illumination Koehler principle All electronic parts for the illumination are integrated into the microscope bas...

Страница 9: ...ia 6 dpt Adjustment Object guide 76 mm x 26 mm Adjustment Gliding stage d 40 mm Coaxial coarse and fine drive Resolution 2 m Microscope Achromatic 160mm Objectives Objectives 4x 10x 20x 40x Eyepiece G...

Страница 10: ...without eyecups The eyepiece is usable as eyepiece for spectacles To avoid dirt within the tube the eyepieces should be stay the whole time in the tube The power connection of the incident light tube...

Страница 11: ...tube 1 3W LED illumination 2 Filter holder opened 3 Adjusting ring for the aperture stop aperture diaphragm 4 Adjusting ring for the illuminated field aperture field diaphragm 5 Intermediate tube RMA...

Страница 12: ...r which is directly mounted into the filter holder of the transmitted light illumination of the microscope The 180 rotatable analyzer slide 1 is can be clamped by the locking screw 3 2 4 3 Compensator...

Страница 13: ...to be set into the tube mount for assembling the tube Don t forget to clamp the screw again If necessary the tubes can be mount also by rotating in 180 It isn t possible to use more than one intermedi...

Страница 14: ...230V After that the base plate can be closed and saved with a screw again and the microscope can be set up 3 2 Care of components 3 2 1 The dioptre rings are unscrewed those threads easily greased an...

Страница 15: ...e adjustable eyepiece will be focused on the reticle 4 2 Tubes 4 2 1 The monocular straight tube is a tube which is used mainly as the second perpendicular observation view in connection with a binocu...

Страница 16: ...s equipped with a 30 angle and image erection IE It is attached between the centre section of the microscope and the straight binocular tube for 160mm Objectives pic 10 angled tube 30 with IE 5 2 Phot...

Страница 17: ...ng software for normal and as well as for microscopic linear measurements The division is on the top side of the plate For calibrating the division is turned to the objective For direct linear measure...

Страница 18: ...to adjustment on the upper exit of the Photo TV tube itself The objective is removed from the camera and the T2 adapter will be mounted there The photo adjustment cannot be adjusted because it is so b...

Страница 19: ...ry In normal case you don t have to change nothing In case you don t have a clear picture you have to follow the instructions at points 8 1 1 and 8 1 2 8 1 1 The TV adapter 1x comes in two parts which...

Страница 20: ...uide pic 17 optics for transmitted light placed in the stand Further it is necessary to use a condenser The condenser comes with a wide field lens and an aperture stop 9 2 Oblique incident light dark...

Страница 21: ...ange of 76 x 26 mm The maximum height of the specimen is 40 mm pic 20 stage carrier with object guide 10 3 Stage carrier with rotary stage The stage carrier with rotary stage is usable for the researc...

Страница 22: ...nation and coaxial coarse and fine drive just measure the object points object levels from only one direction 10 5 2 Depth measurement with the coaxial coarse and fine drive is almost the same as with...

Страница 23: ...23 11 System overview...

Страница 24: ...the conditions The warranty period is 2 years We reserve the right for the product to differ from our brochures as a result of any improvements or alternations for other reasons Such alternations do n...

Отзывы: