7.3.6 Signal and code of warning and mistakes
☼
Pressure
- slow flashing -
Warning:
Pressure near lower limit (0,4bar ≤ P ≤ 0,6bar)
or upper limit (2,2bar ≤ P ≤ 2,6bar) of allowed pressure
Measure:
Bring the system to the necessary pressure value
☼
Pressure
- quick flashing -
Mistake:
Exceeding lower limit (0,3bar ≤ P)
o
r upper limit (P ≥ 2,6bar) of allowed pressure
Measure:
Bring the system to the necessary pressure value
Graphic display of the area of blockade of the boiler work conditioned by the pressure
(1.pressure increases→ / 2.pressure
decreases←)
☼
Temp.
- slow flashing -
Warning:
lower limit exceeding (T≤4 °C) or upper limit (T≥85 °C) of temperature of the
heating system
Measure:
Check if valves are open, the functionality of circulation pump and
relay/contactor
☼
Temp.
- quick flashing -
Mistake:
lower limit exceeding (T≤2 °C) or upper limit (T≥89 °C) of temperature of the
heating system
Measure:
Turn off electric power supply for the boiler. Call service
Graphic display of the area of blockade of the boiler work conditioned by temperature (1.temp. increases→ / 2.temp. decreases←)
Mistake signals on display
EP - Mistake:
Pressure sensor in break or circuit break
– all turned off
Measure:
Turn off power supply. Call service.
EL - Mistake:
Very low boiler temperature or temperature sensor circuit break
– all turned off
Measure:
Turn off power supply. Call service.
EH - Mistake:
Very high temperature (T≥100 °C) not able to display – all turned off
Measure:
Turn off power supply. Call service.
ES - Mistake:
Boiler temperature sensor breaker
– all turned of
Measure:
Turn off power supply. Call service.
Heating installation handling
NORMAL WORK
NORMAL WORK
WARNING
WARNING
WORK BLOCKADE
WORK BLOCKADE
WORK BLOCKADE
WORK BLOCKADE
WORK BLOCKADE
WORK BLOCKADE
WARNING
NORMAL WORK
NORMAL WORK
WORK BLOCKADE
WARNING
WORK BLOCKADE
88
89