![Miki Pulley COUPLINGS Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/miki-pulley/couplings/couplings_manual_1793917017.webp)
19
T h e l a te s t CA D d a t a c a n b e d ow n l o a d e d f r o m o u r we b s i te.
h t t p: // w w w. m i k i p u l l ey.c o. j p/
The CAD mark indicates that CAD data is available by CD-ROM.
The CAD file No. represents the file name in the CD-ROM.
C A D
C A D
S
E
R
V
O F
L
E
X
S
F
C
¢
Selection procedure
Servo motor specification
Compatible coupling specification
Rated output
[kW]
Rated revolution
[min
–1
]
Rated torque
[N·m]
Max. torque
[N·m]
Shaft dia.
[mm]
Single element
Double element
Max. bore
dia. [mm]
Model (SFC-
£
SA2)
Model (SFC-
£
DA2)
0.05
3000
0.16
0.48
8
010SA2
010DA2
8
0.1
3000
0.32
0.95
8
020SA2
020DA2
10
0.2
3000
0.64
1.90
14
030SA2
030DA2
14
0.4
3000
1.30
3.80
14
035SA2
035DA2
16
0.5
2000
2.39
7.16
24
050SA2
050DA2
25
0.5
3000
1.59
4.77
24
050SA2
050DA2
25
0.75
2000
3.58
10.7
22
050SA2
050DA2
25
0.75
3000
2.40
7.20
19
040SA2
040DA2
19
0.85
1000
8.12
24.4
24
060SA2
060DA2
30
1
2000
4.78
14.4
24
050SA2
050DA2
25
1
3000
3.18
9.55
24
050SA2
050DA2
25
1.2
1000
11.5
34.4
35
080SA2
080DA2
35
1.5
2000
7.16
21.6
28
060SA2
060DA2
30
1.5
3000
4.78
14.3
24
050SA2
050DA2
25
2
2000
9.55
28.5
35
080SA2
080DA2
35
2
3000
6.37
15.9
24
050SA2
050DA2
25
3
1000
28.60
85.9
35
090SA2
090DA2
35
3.5
2000
16.70
50.1
35
080SA2
080DA2
35
3.5
3000
11.10
27.9
28
060SA2
060DA2
30
5
2000
23.90
71.6
35
080SA2
080DA2
35
5
3000
15.90
39.7
28
060SA2
060DA2
30
7
2000
33.40
100
35
090SA2
090DA2
35
¢
Simplified selection
Td = Ta × K (see below)
(1) Calculate torque Ta applied to the coupling based on the
motor output P and coupling operating rotation speed n.
Ta [N·m] = 9550 ×
P [kW]
n [min
−1
]
Load character
Constant
Fluctuations: Slight Fluctuations: Medium Fluctuations: Large
1.0
1.25
1.75
2.25
In servo motor drive, multiply the service factor K=1.2 to 1.5
by the maximum torque of servo motor Ts.
Td = Ts × (1.2 to 1.5)
Tn
≥
Td
(2) Calculate corrected torque Td applied to the coupling after
deciding the service factor K based on load conditions.
(5) Confirm if the required shaft diameter does not exceed the
maximum bore diameter of the selected size.
(3) Select a coupling size with permissible torque Tn that
becomes equal or greater than the corrected torque Td.
(4) Depending on the bore diameters, the coupling permissible
torque may be limited. Refer to the “Specification” and
“Standard bore diameter”.
The table indicates suitable sizes based on the rated output, rated torque and maximum torque of general-purpose servo motors. Since
torque characteristics of servo motors differ depending on the manufacturer, select the coupling size after confirming the specification of the
manufacturer.
For machines whose load torques periodically fluctuate
drastically, contact us.
Содержание COUPLINGS
Страница 3: ......