background image

                

Programming manual V1.1

 

 

 

www.parapulser.com 

7

 

 
Display of pulse consumption 

On

/

Off 

switching: 

1.) 

Activate

 Programming-mode

, see “

8

 

a)

 

on page 

2

2.) 

Activate Input-mode:

 

CODE

-key press 

2

 sec., until 

3

 “

Piep!

”-tones are audible. The input-mode is now acti-

vated: the 

red

 LED blinks 

1

x per second and in addition a Piep-tone is audible! 

3.)  2

-digit number “

15

” input: 

Jump to chapter “

8.13

" on page 

11

 and follow the instructions for number entering. Af-

terwards it continues here with point 

4.)

 

4.) 

Acoustic confirmation of 

On

/

Off 

switching: 

Directly after the input of the second digit (number “

5

”), an acoustic signal is audible: 

–  At 

On

 

switching the consumption display, a “

Dulip!

”-signal is audible, 

–  At 

Off

 

switching the consumption display, a long “

Beeeep!

”-tone is audible, 

Afterwards, the input-mode is terminated automatically and all three LED (

=

=

=

) light 

up again. 

 

8.7   

Upgrade-Frequency increase / readout [

16

The upgrade frequency can be increased up to 

20

 Hz against payment, see “

6.2

”, on page 

8

Upgrade-frequency increase: 

1.) 

Order

 6

-digit upgrade CODE-number at your 

Parapulser 

salesman. 

2.) 

Enter the CODE-number as described at “

8.13

”, page 

11

. After successful CODE-input 

the increased upgrade-frequency can be checked by readout right away: 

 
Readout upgrade-frequency (

1

 or 

2

-digit): 

1.) 

Activate

 Programming-mode

, see “

8

 

a)

 

on page 

2

2.) 

Activate Input-mode:

 

CODE

-key press 

2

 sec., until 

3

 “

Piep!

”-tones are audible. The input-mode is now acti-

vated: the 

red

 LED blinks 

1

x per second and in addition a Piep-tone is audible! 

3.)  2

-digit number “

16

” input: 

Jump to chapter “

8.13

” on page 

11

 and follow the instructions for number entering. Af-

terwards it continues here with point 

4.)

.

 

4.) 

Write down the displayed numbers: 
The 

Parapulser

  now  shows  with  help  of  the  LEDs  (

=

=

=

)  the 

first

  digit  of  the  up-

grade-frequency. Write down this number. 

5.) 

Remaining digits of upgrade-frequency readout: 

rest

-key 

short

  press,  and  after  each  actuation,  write  down  the  via  LED  (

=

=

=

)  dis-

played number (

0

 – 

9

) right beside the already noted number(s).  

Repeat  this  procedure  until  a long  “

Beeep!

”-tone  signalizes,  that  all  digits  have  been 

readout. The input-mode is automatically terminated and all three LEDs (

=

=

=

) light 

up again.

 

Содержание Parapulser

Страница 1: ...M a g n e t i c P u l s e r Based on the researches of Dr R C Beck P r o g r a m m i n g V 1 1 04 2018 TAKE BACK YOUR POWER...

Страница 2: ...adout 12 5 8 5 Volume adjustment of operating signals 13 and of the pulse counter 14 6 8 6 Yellow LED ON when consuming pulses 15 6 8 7 Upgrade Frequenz increase readout 16 7 8 8 Software version 17 o...

Страница 3: ...arapulser switch off sel Number 0 9 memory 1 12 select HZ Frequency input activate complete rest Pulse reservoir Frequency value readout set selected number 0 9 confirm CODE Input mode e g for Code nu...

Страница 4: ...into a free memory location 1 Write down the frequency value in the form of a 5 digit number e g 07843 2 Activate Programming mode see 8a on page 2 3 Select free memory location sel key press so ofte...

Страница 5: ...put mode is aborted when the PROG key is shortly pressed after a jump back to a previous digit has taken place see c All so far made inputs will be rejected and the number of the selected memory locat...

Страница 6: ...re audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 4 6 digit number sequence input Jump to chapter 8 13 on page 11 and follow the instr...

Страница 7: ...2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 3 2 digit number 13...

Страница 8: ...rade frequency increase 1 Order 6 digit upgrade CODE number at your Parapulser salesman 2 Enter the CODE number as described at 8 13 page 11 After successful CODE input the increased upgrade frequency...

Страница 9: ...long Beeep tone signalizes that all digits have been readout The input mode is automatically terminated and all three LEDs light up again If the 2 digit software version has been readout the version...

Страница 10: ...t of magnetic pulses Needed pulse amount number of application days x number of daily applications x pulse frequency in Hz x amount of minutes per application x 60 Example How many magnetic pulses are...

Страница 11: ...8 Input of a CODE number 1 Activate Programming mode see 8a on page 2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x...

Страница 12: ...e of numbers with examples 1 1 st digit to be input Hz 0 Pu 1 Co 8 2 2 nd digit to be input Hz 7 Pu 1 Co 4 3 3 rd digit to be input Hz 8 Pu 0 Co 3 4 4 th digit to be input Hz 4 Pu 8 Co 7 5 5 th digit...

Страница 13: ...Power input max 3 5 A max 40 Watt Overvoltage protection invers polarity prot 60 Volt 1 min 30 Volt General data Life expectancy pulse capacitor 5 x 10 9 magnetic pulses Operating temperature range 4...

Отзывы: