background image

                

Programming manual V1.1

 

 

 

www.parapulser.com 

3

 

Chapter

 

Programming-Option 

Number input / -readout 

8.10 

Puls reservoir readout 

A

 

1

 

A

 

2

 

A

 

3

 

A

 

4

 

A

 

5

 

A

 

6

 

A

 

7

 

A

 

8

 

 

 

8.9

 

Test-CODE input 

 

 

 

 

8.10

 

Pulse reservoir refill 

C

1

  C

2

  C

3

  C

4

  C

5

  C

6

 

 

 

 

 

8.7

 

Upgrade-frequency increase 

C

1

  C

2

  C

3

  C

4

  C

5

  C

6

 

 

 

 

 

8.12

 

Unblock-CODE input 

C

1

  C

2

  C

3

  C

4

  C

5

  C

6

 

 

 

 

 

 

 

0

 

...

 

9

  : This number is predetermined and has to be input by the user. 

A

 

1

 

... A

 

8

 

: This number (

0

 – 

9

) is emitted by the 

Parapulser

C

1

 

... C

6

 

: The 

6

-digit CODE-number has to be input by the user. 

Z

 

1

 

... Z

 

5

 

: This number (

0

 – 

9

) has to be choosen and input by the user. 

1)

 

This function is of relevance for the manufacturer only

 

8.2   

Puls frequency programming 

At programming a puls frequency the following rules have to be observed: 

–  Only frequency values between 

1.000

 and 

20.000 

Hz

 

can be entered.  

–  A frequency value has to be entered in the form of a 

5

-digit number without point. 

  Examples

7,840 

Hz becomes to the sequence 

07840

12,667 

Hz becomes to 

12667

.  

 

Program a pulse frequency into a 

free memory location

1.) 

Write down the frequency value in the form of a 

5

-digit number (e.g. 

07843

). 

2.) 

Activate

 Programming-mode

, see “

8

 

a)

 

on page 

2

3.) 

Select free memory location: 

se

l

-key press 

so often shortly

, until the number (

1

12

) of the 

free memory location 

in which you want to enter the frequency value

is displayed via LEDs (

=

=

=

). 

4.) 

Activate Input-mode:

 

HZ

-key  press 

2

  sec.,  until 

3

  “

Piep!

”-tones  are  audible.  The  input-mode  is  now  acti-

vated: the 

red

 LED blinks 

1

x per second and in addition a Piep-tone is audible! 

5.)  5

-digit number sequence input: 

Jump to chapter “

8.13

” on page 

11

 and follow the instructions for number entering. Af-

terwards it continues here with point 

6.)

6.) 

The frequency value has been entered successfully: 
The  input-mode  is  terminated  automatically  and  the  LEDs  (

=

=

=

)  show  again  the 

number (

 12

) of the 

free memory location

, in which the frequency value was pro-

grammed just before. 

Æ

  

1

short 

press of 

PROG

-key, that all 

3

 LEDs (

=

=

=

) light up again. 

7.) 

Adjust

 Parapulser

 to programmed frequency value: 

To use the just programmed pulse frequency, follow the two instructions below: 

Æ

  

Programming-mode

 terminate (preferably without switch off of the 

Parapulser

), see 

 

8

 

b)

 

on page 

2

Содержание Parapulser

Страница 1: ...M a g n e t i c P u l s e r Based on the researches of Dr R C Beck P r o g r a m m i n g V 1 1 04 2018 TAKE BACK YOUR POWER...

Страница 2: ...adout 12 5 8 5 Volume adjustment of operating signals 13 and of the pulse counter 14 6 8 6 Yellow LED ON when consuming pulses 15 6 8 7 Upgrade Frequenz increase readout 16 7 8 8 Software version 17 o...

Страница 3: ...arapulser switch off sel Number 0 9 memory 1 12 select HZ Frequency input activate complete rest Pulse reservoir Frequency value readout set selected number 0 9 confirm CODE Input mode e g for Code nu...

Страница 4: ...into a free memory location 1 Write down the frequency value in the form of a 5 digit number e g 07843 2 Activate Programming mode see 8a on page 2 3 Select free memory location sel key press so ofte...

Страница 5: ...put mode is aborted when the PROG key is shortly pressed after a jump back to a previous digit has taken place see c All so far made inputs will be rejected and the number of the selected memory locat...

Страница 6: ...re audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 4 6 digit number sequence input Jump to chapter 8 13 on page 11 and follow the instr...

Страница 7: ...2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 3 2 digit number 13...

Страница 8: ...rade frequency increase 1 Order 6 digit upgrade CODE number at your Parapulser salesman 2 Enter the CODE number as described at 8 13 page 11 After successful CODE input the increased upgrade frequency...

Страница 9: ...long Beeep tone signalizes that all digits have been readout The input mode is automatically terminated and all three LEDs light up again If the 2 digit software version has been readout the version...

Страница 10: ...t of magnetic pulses Needed pulse amount number of application days x number of daily applications x pulse frequency in Hz x amount of minutes per application x 60 Example How many magnetic pulses are...

Страница 11: ...8 Input of a CODE number 1 Activate Programming mode see 8a on page 2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x...

Страница 12: ...e of numbers with examples 1 1 st digit to be input Hz 0 Pu 1 Co 8 2 2 nd digit to be input Hz 7 Pu 1 Co 4 3 3 rd digit to be input Hz 8 Pu 0 Co 3 4 4 th digit to be input Hz 4 Pu 8 Co 7 5 5 th digit...

Страница 13: ...Power input max 3 5 A max 40 Watt Overvoltage protection invers polarity prot 60 Volt 1 min 30 Volt General data Life expectancy pulse capacitor 5 x 10 9 magnetic pulses Operating temperature range 4...

Отзывы: