7
|
MIJAR
–
WATER TREATMENT |
| Azotowa 15b | 41-
503 Chorzów |
Poland | Tel./fax. 32 2899674 | email: [email protected] | www.mijar.eu |
3.
Installation
After preparation for mounting, the device is to be placed in the designated room in accordance with the
system structure.
All inlets and outlets are to be connected on t
he water‟s side. The device connections are
shown in the
following figure:
·
Connect the inlet (1) and outlet (2) to water supply;
·
Connect the elastic pipe (1/2‟) draining the sewage to the stub connector pipe (
3) and to a sewage
grating or a draining installation.
·
The sewage draining should be permeable enough to drain 5l/m of the flushing water. The draining
pipe should be stiff enough to avoid its breaking, which may cause blockage and result in the
overflow in the tank with the reagent as well as faulty regeneration process;
·
Before water softener should be used mechanical sediment filter to protect device from mechanical
damage caused by sediments from water pipes.
The brine tank of the water softening device is to be filled with salt tablets (max. filling 100 mm from
the upper edge of the brine tank). Next add 5 liters of water using buckets.
Check and tighten all fittings connecting the device.
Connect to electric Power socket.
The device is factory adjusted. The
fine tuning
is done by the user on site.
Program the steering valve (
see point 3.2
)
Before launching the current time should be set and the number of m
3
to flow after which the
regeneration is to start.
Valve is pre-set for intelligent regeneration (down-flow) A-03 (description on page 11)
The Valve is preset for the regeneration at 2 a.m. every 975 liters (0,975 m
3
) for the water
hardness of 20 GH German degrees. Depending on the water hardness set the appropriate
number of liters to flow after which the regeneration is to start (Examine the water hardness and
use the table from the page 5) and set the regeneration time.
Open the
water supply
to the water softening device.
The
water pressure
must be at least 2,0 bars and a maximum of 6,0 bars.
Initiate regeneration by pressing
button You will hear the humming of an electric engine, which
means that device driver has started its regeneration. During the regeneration process the system de-
aerates and refills the reagent tank with water. Once the regeneration is over, the device is ready to work
again. During the regeneration hard water is available.
While programming it is
not allowed
to change : Backwash, Brine and Slow Rinse, Refilling and Fast
Rinsing settings in the
Advanced Settings
stage. These are the manufacturing settings for the Softener
VE system; in case they are changed the system will not work properly and manufacturer shall not be
held liable for the consequence of incorrect operation of the system .
The system has been programmed in A-03 regeneration mode
–
the intelligent, logical regeneration. On
the basis of the water use from the last 7 days the system itself chooses the day of regeneration at the
pre-set time.
Picture 2. Steering valve
description.
1.
Inlet of raw water
(3/4", elastic
connection)
2.
Outlet of treated
water (3/4",
elastic
connection)
3.
Drain (1/2",
elastic
connection).
4.
3/8" brine tank
connection
5.