5
|
MIJAR
–
WATER TREATMENT |
| Azotowa 15b | 41-
503 Chorzów |
Poland | Tel./fax. 32 2899674 | email: [email protected] | www.mijar.eu |
The system is configured to use 1,0 kg of reagent per each regeneration.
Calculating the amount of softened water between regenerations:
The amount of water between regenerations is calculated according to this formula:
Z = 1950x10/y
Where
Z
–
is the amount of softened water between regenerations
Y
–
is the examined water hardness according to „n (German degree)
An example of calculation the amount of softened water „z‟ between regeneration.
Data: the examin
ed water hardness = 15‟n
The amount of „z‟ water between regenerations is calculated according to the formula:
Z = 1950 x 10/15 = 1300 liters.
At the water hardness of 15‟GH we get
1300 liters of softened water.
TAB. 1. CAPACITY
–
MiniBoy VE
Water hardness
English degree
French degree
PPM
German degree
Efficiency MiniBoy VE
12,5
18
178,6
10
1950
13,8
19,8
196,5
11
1773
15
21,6
214,3
12
1625
16,3
23,4
232,2
13
1500
17,5
25,2
250
14
1393
18,8
27
267,9
15
1300
20
28,8
285,8
16
1219
21,3
30,6
303,6
17
1147
22,5
32,4
321,5
18
1083
23,8
34,2
339,3
19
1026
25
36
357,2
20
975
26,3
37,8
375,1
21
929
27,5
39,6
392,9
22
886
28,8
41,4
410,8
23
848
30
43,2
428,6
24
813
31,3
45
446,5
25
780
32,5
46,8
464,4
26
750
33,8
48,6
482,2
27
722
35
50,4
500,1
28
696
36,3
52,2
517,9
29
672
37,5
54
535,8
30
650
38,8
55,8
553,7
31
629
40
57,6
571,5
32
609
41,3
59,4
589,4
33
591
42,5
61,2
607,2
34
574
43,8
63
625,1
35
557
45
64,8
643
36
542
46,3
66,6
660,8
37
527
47,5
68,4
678,7
38
513
48,8
70,2
696,5
39
500
50
72
714,4
40
488
The stated capacities were calculated based on standard application and machine conditions. This information
may vary according to external influencing factors (for example, fluctuating raw water quality).