MM362 Installation Instructions
17
Step 3
Press and HOLD the 1st opener JOG CLOSE button
on the control board and be prepared to RELEASE
the button when the gate reaches the desired closed
position/limit. Use the JOG OPEN and CLOSE buttons to
"fine tune" the gate position if necessary.
Step 4
With the gates in in the desired closed positions PRESS
and HOLD the SET LIMIT button until the alarm and RED
Light come on. Then release the button.
NOTE: The opener must be extended more than 7
inches to set limits.
Step 5
NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet.
Press the transmitter button once (within 5 feet of the control board) and allow the gates to fully open. The alarm will beep
once when both gates reach the OPEN LIMIT. This indicates the limits for both arms are programmed in memory.
Step 6
Press the transmitter button and allow the gates to fully close to verify that they stop at the desired positions. Repeat Steps
2-5 if correction is needed.
NOTE: If the gate stops and reverses you may need to adjust the Stall Force (see below).
MIN
MAX OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
FIRST Opener
JOG Buttons
SET LIMIT Button
SET LIMIT Light
SECOND Opener
JOG Buttons
Setting Dual Sense Detection and Auto Close Timer
Do not use the Dual Sense Stall Force adjustment to compensate for a
gate that is sticking or binding. Excessive Stall Force may cause damage
to the gate operator or gate system or Injury or Death.
The Stall Force adjustment controls the amount of force the opener will
apply against an obstruction before it stops and reverses direction. The
adjustment on the control board operates like a volume control on a radio.
It controls the amount of force the opener will apply to an obstruction
before it automatically reverses direction.
The Stall Force adjustment is located on the control board. Turn the “STALL
FORCE” arrow in the center of the potentiometer with small flat head
screwdriver. Adjust the sensitivity from the MINIMUM position up to the
point where the gate operates without obstructing from its own weight or
the wind conditions in your area.
NOTE:
You may need to increase the stall force in cold weather due to increased resistance from gate hinges. However,
the adjustment must remain as near to minimum as possible and when the weather improves decrease the setting to the
appropriate position.
Set Auto-Close Time
The Auto-Close determines how long the gate will remain open before
it automatically closes. The factory setting is OFF. Use a small flat blade
screwdriver, you can adjust the settings to OFF, or from 3 to 120 seconds.
NOTE: Auto-Close timer is disabled (gate will not automatically close) if
gate is not at the fully open position.
VAR5
VAR6
K1
PF1
K2
BATT
+
BATT
–
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX OFF
JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
G
TO Inc.
Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR
.
FIRST OPR
.
RED
BLK
14 VAC
OR
SOLAR
ON OFF
MIN
MAX
STALL FORCE
VAR5
VAR6
K1
PF1
K2
BATT
+
BATT
–
K3
K4
VAR4
VAR3
VAR2
VAR1
MIN
MAX OFF
JP1
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
G
TO Inc.
Tallahassee, FL
R4722
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR
.
FIRST OPR
.
RED
BLK
14 VAC
OR
SOLAR
ON OFF
OFF
120
SEC.
AUTO CLOSE
For safety reason the Dual Sense Stall Force setting on the Mighty Mule control board comes from the factory set at MIN (minimum). This
setting may need adjustment depending on the size and weight of the gate.
ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR GATE SYSTEM.
CAUTION