Connect Opener Power Cables

Step 1

Bring FIRST power cable into the control box through a strain relief slot, 

leaving enough wire to reach the FIRST OPR. terminal block.
Insert the individual power cable wires into appropriate terminals on the 

FIRST OPR. terminal block (white to WHT; green to GRN; red to RED; 

black to BLK). Tighten the set screws. A dab of petroleum jelly on each 

terminal will help prevent corrosion.

Step 2

Pull the 36' second opener power cable through the PVC conduit and 

secure in the driveway slot/trench (see pages 6 and 14). 

Step 3

Insert the SECOND power cable into a strain relief slot at the bottom 

of the control box, leaving enough wire to reach the SECOND OPR. 

terminal block. 
Insert the individual power cable wires into appropriate terminals on 

the SECOND OPR. terminal block (white to WHT; green to GRN; red to 

RED; black to BLK). Tighten the set screws. 

Connect the Transformer 

(*Solar Instructions on Page 21)

NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!

IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE:

 

•  The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct burial wire. This 

particular gauge enables the transformer to provide an adequate charge through the control board to the battery 

at distances up to 1000'.

 

•  DO NOT use telephone wire or solid core wire. Unlike stranded wire, these types of wire are inadequate for use 

with your gate opener system.

 

•  NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an 

adequate current. 

Step 1

Make sure the power switch is OFF.

Step 2

Select the electrical outlet where you will plug the transformer. Measure 

the distance from this outlet to the control box following the path 

where the wire will be laid. After you have measured how much wire is 

needed, cut the wire to the appropriate length  (up to 1000').

FIRST Opener

Power Cable

SECOND Opener

Power Cable

Strain Relief Slots

(Battery Wires Not Shown)

VAR5

VAR6

K1

PF1

K2

BATT 

+

BATT 

K3

K4

VAR4

VAR3

VAR2

VAR1

MIN

MAX OFF

JP1

REMOVE JUMPER FOR

PUSH TO OPEN OPTION

120

SEC.

G

TO Inc.   

Tallahassee, FL

R4722

STALL FORCE

OPEN  <  JOG  >  CLOSE

PWR.

SET

LIMIT

1st  OPR.

2nd  OPR.

STATUS

AUTO CLOSE

SFTY.

EXIT

CYCLE

EDGE

SENSOR

COMMON

LOCK+

LOCK–

WHT

GRN

RED

BLK

WHT

GRN

SECOND OPR

.

FIRST OPR

.

RED

BLK

14 VAC

OR   

SOLAR

ON  OFF

Correct

Wrong

Screwed into 

wire insulation.

Exposed strands

of wire.

Wrong

Wire Terminal 

Block

ON/OFF

Switch

ON/OFF

Содержание FM402

Страница 1: ...e not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value READ ALL INSTRUCTIO...

Страница 2: ...al General Access Vehicular Gate Operator Class II A vehicular gate operator or system intended for use in a commercial location or building such as a multifamily housing unit five or more single fami...

Страница 3: ...tallation Overview for Pull To Open Gates 6 Installation of the First Gate Opener 7 Install Post Bracket Assembly and Gate Bracket 8 Attach Opener Arm 10 Install the Closed Position Stop Plates 11 Mou...

Страница 4: ...it stops and reverses direction You will need to adjust the stall force for your particular application The Mighty Mule Gate Opener also has an adjustable auto close feature After the gate reaches the...

Страница 5: ...symbol The symbol identifies conditions that can result in damage to the opener or its components serious injury or death Because GTO automatic gate openers are only part of the total gate operating...

Страница 6: ...er is proper for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace all...

Страница 7: ...e Area Driveway 10 10 10 10 10 10 NEVER INSTALL any control device within gray area III After Installation 1 Attach the warning signs included to each side of the gate to alert the public of auto mati...

Страница 8: ...ccess Systems LLC at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Safety Precautions...

Страница 9: ...apment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction A wireless contact se...

Страница 10: ...front and rear mount from mounting brackets 3 Remove opener from mounting brackets and move gate Disconnect opener ONLY when the power switch is OFF and the gate is not moving www mightymule com 1 800...

Страница 11: ...rol board regulates charging Sleep draw is 15 mA active draw is 3 to 8 A Auto memorization of digital transmitter code GTO RF receiver tuned to 318 MHz Opener length with push pull tube fully retracte...

Страница 12: ...If your gate is more than 1000 from an AC power source you will need to use a solar panel charging kit minimum 10 watts Refer to the Solar Panels and Gate Activity Chart below Solar Panel and Gate Ac...

Страница 13: ...should have ball bearing hinges with grease fittings The gate post should be be secured in the ground with concrete so it will minimize twist or flex when the opener is activated The addition of a ho...

Страница 14: ...stallation DVD 1 Gate Bracket 2 Post Pivot Bracket 2 3 8 Bushings 2 Customer Support Card 1 Post Bracket 2 Closed Position Stop Plate 2 2 Mounting Screw 6 E Z GATE OPE NER Transformer 1 Warning Signs...

Страница 15: ...he control box Page 14 26 If your gate is more than 1000 away from an AC power source you will need to use at least one 10 Watt solar panel FM123 or two 5 Watt panels FM121 to charge the 12 Volt batte...

Страница 16: ...ackets allows for 1 of clearance between the gate and the opener in both the open and closed position at the same time maintaining a maximum distance of 13 from the end of the retracted opener arm to...

Страница 17: ...netrate the post On wood posts place a metal plate or washer not supplied between the nuts and the post to prevent the thrust of the opener from pulling the bolts and washers out of the wood The post...

Страница 18: ...ener with a clevis pin and a 3 8 bushing Secure the clevis pin with a hairpin clip Step 4 With the gate in the fully open position and the opener arm fully retracted adjust the post bracket assembly a...

Страница 19: ...move the 5 16 x 11 2 bolt and readjust the post pivot bracket TIP Turn the post pivot bracket over for more hole alignment options You can also move the entire post bracket assembly to different posit...

Страница 20: ...Post Remove excess bolt length with hacksaw or bolt cutters SIDE VIEW TOP VIEW EXAMPLES Gate Bracket Mounting Examples Attach Opener Arm Step 1 Attach the opener to the securely bolted post bracket as...

Страница 21: ...gates and move the gates to the closed position Step 2 Using appropriate hardware for your type of gate U bolts for tube or chain link screw or bolts for wood or metal attach the closed position stop...

Страница 22: ...ition Stop Plate Low Profile Ground Stop Closed Position Stop Plate Step 4 Using appropriate hardware for your type of gate attach the vertical closed position stop plate to the SECOND gate frame at t...

Страница 23: ...L BOX Battery Back of Control Box Battery Wire Harness with In Line Fuse Step 5 Tuck the excess battery leads into the battery box and reattach the CONTROL BOX to the BATTERY BOX Step 6 Remove the fou...

Страница 24: ...is 16 gauge stranded low voltage direct burial wire This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 DO NOT...

Страница 25: ...ten set screws against exposed end of wires Step 6 At the AC outlet strip 1 2 of insulation from the ends of the low voltage wire Attach these stripped ends to the transformer terminals We suggest add...

Страница 26: ...ine tune the gate position if neccessary Step 4 With the gates in in the desired closed positions PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on Then release the button NOTE...

Страница 27: ...t of force the opener will apply against an obstruction before it stops and reverses direction within two seconds IMPORTANT The Stall Force setting will need to be adjusted to compensate for the weigh...

Страница 28: ...o less than 5 feet FCC WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment In accordan...

Страница 29: ...This mounting position will give the opener the most efficient leverage point for operation and provides the least possible pinch area C After verifying that you have the best position for the post p...

Страница 30: ...neccessary C Press and HOLD the SECOND Opener OPEN button on the control board and be prepared to RELEASE the button when the gates reached the desired open position limit Use the JOG OPEN and CLOSE b...

Страница 31: ...sert one solar panel wire into a 14VAC OR SOLAR terminal Insert the other solar panel wire into the remaining 14VAC OR SOLAR terminal The wires can be connected to the 14VAC OR SOLAR terminals regardl...

Страница 32: ...Safety Devices Photo Beams Push Button Control Gate Opening Sensor Refer to Sensor manual for additional information if needed Edge Sensor Automatic Gate Lock NOTE Connections are for typical applica...

Страница 33: ...ll cycle the operation as follows OPEN STOP CLOSE STOP OPEN 4 EDGE SENSOR Typically for use with contact edge sensor Activation of this input while gate is moving will cause it to reverse direction fo...

Страница 34: ...elf test when the unit is turned on b Continuous beep after power up Unit has learned new transmitter code releasing the transmitter button will shut off the alarm c Rapid beeping Unit has encountered...

Страница 35: ...to solve the problem call the GTO Service Department at 800 543 1236 or 850 575 4144 Refer to the serial number located on the back of opener arm and date of purchase when calling for assistance 4 If...

Страница 36: ...ich offers hands free operation of the Mighty MuleGate Openor with a 12 ft radius of detection of vehicles in motion A wireless version of the Gate Opening Sensor is available FM130 Automatic Gate Loc...

Отзывы: