background image

del

1

211020010

31

Control panel

1

605*185

C-G24-NG(LP)

211020020

28

905*185

C-G36-NG(LP)

211020030

28

1215*185

C-G48-NG(LP)

2

211020010

21

Catch tray

1

490*196*25

C-G24-NG(LP)\

36-NG(LP)\48-

NG(LP)

3

301140001

Kirsite knob

2

C-G24-NG(LP)

3

C-G36-NG(LP)

4

C-G48-NG(LP)

4

301081006

Galvanized

American

outside six

corner with

pad tapping

34

ST4.8*12.5

C-G24-NG(LP)\

36-NG(LP)\48-

NG(LP)

5

212020010

02

bottom border

package

1

610*670*25

7

C-G24-NG(LP)

212020020

02

910*670*25

7

C-G36-NG(LP)

212020030

02

1220*670*2

57

C-G48-NG(LP)

6

301080002

Galvanized

flange face nut

6

M6

C-G24-NG(LP)

8

C-G36-NG(LP)

10

C-G48-NG(LP)

7

301082001

Galvanized flat

grommet

4

φ6*φ10

C-G24-NG(LP)

5

C-G36-NG(LP)

6

C-G48-NG(LP)

8

301030002

A18 stopcock

2

A18-318

C-G24-NG(LP)

3

C-G36-NG(LP)

4

C-G48-NG(LP)

9

301040008
301040009

A18

nozzle(NG)

A18 nozzle(LP)

2

NG37

LP51

C-G24-NG(LP)

3

C-G36-NG(LP)

4

C-G48-NG(LP)

10

301030001

Pilot light

valve-single

2

AP7-1

C-G24-NG(LP)

3

C-G36-NG(LP)

16

Содержание C-G24-LP

Страница 1: ...Gas Countertop Griddles Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards...

Страница 2: ...this instruction manual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final...

Страница 3: ...ief Instruction 3 3 Manufacture s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Operating In...

Страница 4: ...hould not be operated by those under 18 years of age or those with physical or mental disorders or disabilities that lack the necessary knowledge or experience unless with appropriate instructions and...

Страница 5: ...ed personnel Not obey the local law using this product Be repaired or changed by unauthorized technicians Use the spare parts or accessories provided by non manufacturers Accidents caused by force maj...

Страница 6: ...C G48 NG LP 4 2 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The external thread of product s 5...

Страница 7: ...rosive gases warehouse When equipment needs temporary storage waterproof measures should be taken 6 Installation and Debugging Any erroneous installation adjustment refit overhaul or maintenance may c...

Страница 8: ...Fire Protection Association Inc when it comes to requirements for installation of equipment Screw 4 adjustable stainless steel legs in the tapping hole at four corners of the char broiler bottom ensu...

Страница 9: ...install needle type pressure joint screw arbor Important make sure screw up the needle valve to prevent gas escape 6 2 Debugging It s very important to debug the new stove Through the comprehensive sy...

Страница 10: ...take apart any spare parts without authorization Never change any other parts without authorization to this equipment otherwise may cause hazards and the manufacturer has the right not to provide warr...

Страница 11: ...nguish flame of the main burner but the pilot light still works After turning off the equipment the main fire should be stop more than 5 minutes before next using 8 4 Stove Operation Before using the...

Страница 12: ...se in the process of moving and translation Reinstall control panel Caution Each burner damper has been adjusted before delivery once air input normal use without adjustment but only switching gas Adj...

Страница 13: ...and place it in a well ventilated area Comprehensively check the equipment at least once every year by authorized and licensed technicians The product is made of 90 metals and can not be discarded eve...

Страница 14: ...ot light but not the main fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 The main fire nozzle occlusion 2 Dredge nozzle 3 Gas control valves have problems 3 Change gas...

Страница 15: ...es flow Turn it up after the peak The problems mentioned above are only for reference If any fault occurs please stop using and contact technicians to check and repair Safety first turn off the power...

Страница 16: ...Fig 8 Table 4 No Matters Code Component name Qty Dimensio ns mm Mo Remark 15...

Страница 17: ...G LP 5 212020010 02 bottom border package 1 610 670 25 7 C G24 NG LP 212020020 02 910 670 25 7 C G36 NG LP 212020030 02 1220 670 2 57 C G48 NG LP 6 301080002 Galvanized flange face nut 6 M6 C G24 NG L...

Страница 18: ...d 2 A73007 TiP 4 7 C G24 NG LP 3 C G36 NG LP 4 C G48 NG LP 16 212020010 01 countertop 1 610 700 21 8 C G24 NG LP 212020020 01 910 700 21 8 C G36 NG LP 212020030 01 1220 700 2 18 C G48 NG LP 17 3010100...

Страница 19: ...ctions 1 piece 1 piece 1 piece Notice 1 Pressure maintaining valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut F...

Страница 20: ...I TAT I ON Our products have the advantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the de...

Страница 21: ...Service Call 800 852 5292 Service Email warranty mgiali com 20...

Отзывы: