After cooking
^
If you switch off all of the cooking
zones, the cooker hood will also
switch off after a slight time delay.
This delay will allow any lingering
vapours or odours in the air to be
removed.
– If the cooker hood is operating on
power level "4" it will revert to power
level "3" immediately.
– If it is operating on power level "3" it
will switch to power level "2" after
approx. 1 minute.
– From power level "2" it will switch to
power level "1" after 2 minutes.
– Then after 2 minutes operating at
power level "1", the fan will switch off.
– The lighting will go out 30 seconds
later.
Manual operation
^
If you want to operate the cooker
hood manually, switch the cooker
hood fan on
before
switching on the
hob.
^
You can also come out of automatic
mode during cooking, by
– manually selecting a different fan
power level.
– manually switching off the cooker
hood.
– activating the run-on option "
–
" on
the cooker hood.
The fan will then switch off after the
run-on time selected.
The lighting will remain on.
While the automatic mode is
deactivated, you can operate all the
cooker hood functions manually.
Reverting to automatic mode
^
The cooker hood will revert to auto-
matic mode, if –
– after manually selecting a fan power
level, you do not operate the cooker
hood for approx. 2 minutes.
– the fan power level you have
selected manually is the same as the
power level which is selected
automatically.
– the cooker hood fan and the hob are
switched off for at least 20 seconds.
Automatic mode will start again the
next time the hob is switched on.
en - Operation