Guide to the machine
Start
X
button
Press to start the selected programme.
End
7
button
Pressing on this button halts a pro-
gramme (Stop mode). Pressing once
again on the button immediately termi-
nates a programme. A halted pro-
gramme can be continued in the relevant
programme stage by pressing Start
X
button.
Cursor
1
2
buttons
The cursor buttons
1
2
are used to
scroll forwards or backwards into the
input fields or onto the next display (this
appears as > < flashing in the display).
After the start of the programme it is
possible in Stop mode to scroll block by
block backwards or forward in the pro-
gramme. Pressing continuously on the
button scrolls quickly through the op-
tions.
4
Plus
3
Minus buttons
Once an input field has been selected it
is possible to make a modification. Press-
ing continuously on the button runs
quickly through the options.
Delay start
W
button
If this button is pressed before the start
of a programme, the display indicates
that a start time should be selected. If
the button is pressed again the Delay
start option is cancelled.
If this button is pressed after the start of
a programme the current time of day and
date are shown.
9
Optical interface
Data transfer to and from the machine’s
controls and a PC can take place using
the relevant software. Connection is
made via the optical interface on the con-
trol panel.
Emergence Stop Switch
Only to be used in an emergency.
After removing the cause of danger this
switch can be re-set by turning the
ribbed disc in a clockwise direction.
After re-setting the following appears in the
display:
PROGRAMME 1
TH-Disinfection
PROGRAMME STOP
THROUGH POWER CUT
Please press the Start button.
The drum turns to the "Unclean side".
Press the Start
X
button again to continue
the interrupted programme.