Technical Information
58
T1302, T1303, T1322, T1329ci, T1323c,
T1403 and T1405 Clothes Dryers
3 Fault
Repair
3.1
Long Drying Time
Cause
The Condenser Box is clogged blocking the air flow.
Remedy
Clean the Condenser Box (055 4.1).
3.2
Water Leaking from appliance
Cause
Fault in Condenser Water Path
Remedy
Check Condenser Water Path hoses and connections.
Check Float Switch for proper operation.
Check Drain Pump for proper operation.
If drained externally check Drain Hose for proper routing. Ensure
Hose is free of sharp bends and kinks.
4 Service
4.1
Condenser Box - Cleaning
The access panel to the condenser is located on the front lower left
corner of the dryer (Figure 055-4).
1. Press on the lower corners of the access panel and lower it
down.
2. Remove the access panel.
3. Refer to Figure 055-5. Turn the condenser door lock down and
remove the door.
4. Refer to Figure 055-6. Turn the condenser lock up.
Содержание TOUCHTRONIC T 1303