Technical Information
27
T1302, T1303, T1322, T1329ci, T1323c,
T1403 and T1405 Clothes Dryers
2.3
Heating
2.3.1
Heater Bank
The Heater Bank uses two independently controlled elements (R1
and R2). AC power to elements is controlled by the Electronic via
two independent Heater Relays.
2.3.2
Heater Bank Temperature Sensor
The temperature of the Heater Bank is monitored by the Electronic
via the Temperature Sensor mounted at the top of the Heater Bank
Assembly. Refer to 030 1.1 for further operating information.
2.3.3
Thermostats (Temperature Limiters)
Two electrically isolated safety thermostats are mounted at the top
of the Heater Bank Assembly. Both devices interrupt power to the
elements should the temperature exceed a specific temperature.
Note
The thermostats are non-resetable SOD (Single Operation
Devices). Should the device electrically open the circuit– it must be
replaced.
3 Fault