Remedy
A
Disconnect power to the vacuum cleaner (pull the plug) and let the motor cool
off for approximately 20 to 30 minutes.
A
To speed up the cooldown process, open the lid to the dust compartment and
take out the dust compartment filter.
A
Check the suction hose for clogs.
A
Check that the motor turns freely when rotated by hand.
A
Replace any extremely dirty dustbags or exhaust and pre-motor filters.
A
Check the function of the vent; the spring must be able to move freely.
A
Do not switch the motor on again; see Motor Replacement, 050 4.2.
Cause
Carbon brushes are used up.
Remedy
A
Replace the motor; see Motor Replacement, 050 4.2.
Note
The motor's built-in thermal limiter (F2) and carbon brushes are part of the motor
assembly and can
not
be exchanged separately.