Installation and planning notes  

Installation requirements 

Electrical connection should only be made to a power supply provided 
in accordance with all appropriate local and national legislation and 
regulations. 

In addition, all regulations issued by the relevant utilities as well as 
standards relating to occupational safety and all applicable valid 
regulations and technical standards must be observed. 

Transportation and site access 

The washing machine must not be moved without the transit bars in 
place. Keep the transit bars in a safe place. They must be re-fitted if 
the machine is to be moved again (e.g. when moving house). 

General operating conditions 

Ambient temperature in installation room: +2 °C to +35 °C. 

Depending on the nature of the installation site, sound emissions and 
vibration may occur. Miele recommends consulting a specialist if 
particular requirements apply at the installation site with respect to 
sound emissions. 

Electrical connection 

Depending on the model, the machine is delivered with a supply lead 
with/without a plug. 

The appliance may only be connected to an electrical system that 
conforms to the national and local codes and regulations. The 
installation must be performed by a suitably qualified and competent 
electrician. 

The data plate indicates the nominal power consumption and the 
appropriate fuse rating. Compare the specifications on the data plate 
with those of the electrical power supply. 

The appliance can either be hard-wired or connected using a plug-
and-socket connection. It is always recommended to connect the 
machine via a plug and socket so that electrical safety checks, e.g. 
during repair or service work, can be carried out easily. 

If the appliance is hard wired, an all-pole disconnection must be 
provided on site. The means of disconnection must be incorporated in 
the fixed wiring in accordance the the wiring rules. When switched off, 
there must be an all-pole contact gap of at least 3 mm in the isolator 
switch (including circuit breakers, fuses, and relays according to 
AS/NZS 3000). 

The plug connector or isolator switch should be easily accessible at all 
times. If the appliance is disconnected from the electricity supply, the 
isolator must be lockable or the point of disconnection must be 
monitored at all times. 

New connections, modifications to the system or servicing of the 
earthing conductor, including determining the correct fuse amperage, 
must be carried out by a qualified electrician, as they are familiar with 
the pertinent regulations and the specific requirements of the electric 
utility company. 

The appliance must not be connected to devices such as timers which 
would switch it off automatically. 

References to cable cross-sections in the technical data refer only to 
the required mains cable. Please consult relevant local and national 
regulations when calculating any other wire gauges. 

Cold water connection

 

The washing machine must be connected to the mains water supply in 
accordance with current local and national safety regulations and via a 
non-return valve which is supplied separately with the machine. 

Connection to the mains water supply should incorporate a mains tap 
with a threaded union. The tap should be fitted by a qualified plumber. 

A suitable connection hose with a threaded union is provided with the 
machine. 

Longer hoses (2.5 or 4.0 m in length) are available from Miele as 
separate parts (available depending on country). 

Hot water connection 

The same connection requirements as for cold water also apply to hot 
water (max. 70 °C). 

A suitable connection hose with a threaded union is provided with the 
machine. 

The hot water connection appliance also requires a cold water 
connection. 

In the event that hot water is not available on site, connection of the 
second hose must be made to a cold water supply. 

Alternatively, the hot water connection should be blocked using the 
enclosed blind stopper and the machine controls set to cold water 
intake.  

The required amount of hot water should be added to the cold water 
volume. 

Drain valve (depending on model) 

The washing machine is drained using a motorised drain valve. The 
machine can be connected directly to the on-site drainage system 
(without a siphon) or via a floor drain (gully with odour trap). 

A vented drainage system is vital for unimpeded drainage. If on-site 
venting is insufficient, a vent kit (Mat. no. 05 239 540) is available from 
Miele. 

If several machines are connected to a single drain pipe, this should 
be sufficiently large to allow all machines to drain simultaneously. 

Drain pump (depending on model) 

The suds are drained through a drain pump with a 1 m delivery head. 
For the water to drain freely, the hose must be free of kinks.  

 

Drain hose connection options 

1. Connected securely to a trapped waste pipe. 

2. Connected over the rim of the laundry trough or into the sud-saver 
pipe of the laundry trough. 

3. Connected securely to a floor drain (gully). 

Содержание PWM 507 DP Hygiene/Special

Страница 1: ...PWM 507 DV DP PWM 507 DV DP Hygiene Special It is essential to read the operating and installation instructions before installation and commissioning This prevents both personal injury and damage to the appliance en AU NZ 11 284 900 00 ...

Страница 2: ...rofessional com au Miele Global Headquarters Germany Carl Miele Straße 29 33332 Gütersloh Federal Republic of Germany Legend Connection required Connection optional or required depending on model DV Drain valve KW Cold water connection AW Waste water connection DP Drain pump B Appliance anchoring PA Equipotential bonding DOS Dispenser connection SLA Peak load connection EL Electrical connection UG...

Страница 3: ...PWM 507 en AU NZ 11 284 900 00 3 Appliance dimensions F F F F F F F F EL KGA SLA XKM DP DV KW WW DOS PA ...

Страница 4: ...PWM 507 en AU NZ 4 11 284 900 00 Installation EL WW KW KG DV DP KG WW KW EL DP DV KGA SLA EL WW KW KG DP UO UG DV UO UG KG WW KW EL DP DV KGA SLA ...

Страница 5: ...PWM 507 en AU NZ 11 284 900 00 5 Washer dryer stack F F EL WW KW DP DV EL KGA SLA WW KW DV F F APCL APCL ...

Страница 6: ...PWM 507 en AU NZ 6 11 284 900 00 Installation 305 145 5 145 5 681 1031 B B B B BS B B 305 145 5 145 5 305 1031 B B 148 148 305 148 148 BS ...

Страница 7: ...PWM 507 en AU NZ 11 284 900 00 7 Installation UO UG B B UO UG B B UO UG B B B B UO UG B B B B ...

Страница 8: ...00 Required flow rate cold water connection only l min 11 11 11 11 Required flow rate with additional hot water connection l min 10 10 10 10 Connection to be provided on site external thread according to AS 3688 flat seal Inch Connection hose with threaded union Connection hose length mm 1550 1550 1550 1550 Hot water WW Max water intake temperature C 70 70 70 70 Permissible water flow pressure kPa...

Страница 9: ...ength mm 12 x 60 12 x 60 12 x 60 12 x 60 Plinth floor anchoring to be provided on site Appliance installation on on site base concrete or masonry Min plinth installation footprint W D mm 600 650 600 650 600 650 600 650 Wood screws according to DIN 571 mm 6 x 50 6 x 50 6 x 50 6 x 50 Wall plugs diameter x length mm 8 x 40 8 x 40 8 x 40 8 x 40 Appliance data Overall appliance dimensions H W D mm 854 ...

Страница 10: ...f the earthing conductor including determining the correct fuse amperage must be carried out by a qualified electrician as they are familiar with the pertinent regulations and the specific requirements of the electric utility company The appliance must not be connected to devices such as timers which would switch it off automatically References to cable cross sections in the technical data refer o...

Страница 11: ... required for connecting a payment system can be carried out during the initial commissioning process After initial commissioning changes can only be made by your Miele dealer or by Miele Professional Service Interface The appliance can be fitted with an XKM 3200 WL PLT communication module This module can be used as a Wi Fi or LAN interface The LAN interface provided via the module complies with ...

Отзывы: