Optional modules
49
Dispenser calibration
Dispenser pump 1
0/1
0
t:
P: No
100 ml
V:
s
Press multifunction button 0/1.
Stop the pump by pressing button 0/1, or the pump will stop
automatically after 60 seconds.
Measure the required amount into the measuring vessel.
Dispenser calibration
Dispenser pump 1
0/1
30 s
t:
P: 200 ml/min
V:
100 ml
Enter the amount measured in field "V:".
The throughput P is calculated in ml/min by the controls.
Press the
"Save" button.
The measured value is assigned to the pump.
Reattach the hose.
Cleaning and maintenance of the dispensing system
Rinse the dispensing system through with warm water every 2 weeks,
or before shutting the dispenser pumps down for any length of time,
to avoid the system getting clogged up and corroded.
Also rinse out the siphons with water.
Put the siphons in a container of warm water (40-50 °C).
Use dispenser calibration to activate each pump until the
dispensing system is rinsed through.
Check the connection points, hoses, dispensing sockets and
washers for leaks.