Electrical connection U.K.
All electrical work must be carried out
by a suitably qualified and competent
person, in strict accordance with
current national and local safety
regulations (BS 7671 in the UK).
Ensure power is not supplied to the
machine until after installation work has
been carried out.
The voltage, rated load and fuse rating
are given on the data plate. Please
ensure these match the site mains
supply.
This washer-extractor is supplied as
standard for connection to either:
– 230 - 240 V / 1 N / 50 Hz,
25 A fuse rating
or:
– 400 V / 2N / 50 Hz,
2 x 13 A fuse rating
Connection should be made via a
suitable isolator which complies with
national and local safety regulations,
and the on/off switch should be easily
accessible for servicing work.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA (in accordance
with DIN VDE 0664, VDE 0100, Section
739).
When switched off there must be an
all-pole contact gap of 3 mm in the
isolator switch (including switch, fuses
and relays acc. to VDE 0660).
Important
for
400 V
connection, the machine is
supplied with a cable in the following
colours:
Black = live
Brown = live
Blue = neutral
Green and yellow = earth
WARNING
THIS APPLIANCE MUST
BE EARTHED
,
Do not use devices to turn the
machine off automatically, (e.g. auto-
matic timers).