background image

PW 6055/6065 

en -  

 = standard, 

 = optional, + = only upon enquiry, - not available 

10 145 220 / 01 

 

11 

Technical Data 

 

PW 6055 AV 

PW 6055 LP 

PW 6065 AV 

PW 6065 LP 

Drum volume 

 

54  l 

54 l 

59 l 

59 l 

Filling weight 

 

12 lb (5.5 kg) 

12 lb (5.5 kg) 

14.3 lbs (6.5 kg) 

14.3 lbs (6.5 kg) 

Loading door, diameter 

 

11 1/8“ (282 mm)  11 1/8“ (282 mm)  11 1/8“ (282 mm)  11 1/8“ (282 mm) 

Max. spin speed 

 

1400 RPM 

1400 RPM 

1400 RPM 

1400 RPM 

g-factor 

 

526 

526 

526 

526 

Residual moisture (standard load) 

 

49% 

49% 

49% 

49% 

 

 

 

 

 

 

Electrical connection (EL) 

 

 

 

 

 

Standard voltage (US only) 

 

2 AC 208-240 V 

Frequency 

 

60 Hz 

Total connections 

 

4.0 kW 

Fuse protection 

 

2 x 30 A 

Connection cable, minimum cross-section  

 

4 x AWG 10 mm² 

Connection cable without plug for permanent wiring 

 

 

Connection cable, length 

 

6‘ 6 ¾“ (2000 mm) 

 

 

 

 

 

 

Standard voltage (CDN only) 

 

2 AC 208 V 

Frequency 

 

60 Hz 

Total connections 

 

4.0 kW 

Fuse protection 

 

2 x 20 A 

Connection cable, minimum cross-section  

 

4 x AWG10 mm² 

Connection cable without plug for permanent wiring 

 

 

Connection cable, length 

 

6‘ 6 ¾“ (2000 mm) 

 

 

 

 

 

 

Cold water (KW)

 

 

 

 

 

 

Permissible water flow pressure 

 

100 

– 1000 kPa 

100 

– 1000 kPa 

100 

– 1000 kPa 

100 

– 1000 kPa 

Required volume flow (cold water connection only) 

 

11 l/min 

11 l/min 

11 l/min 

11 l/min 

Required volume flow (for additional hot water connection) 

 

10 l/min 

10 l/min 

10 l/min 

10 l/min 

Average water consumption (60°C standard program) 

 

36 l/h 

36 l/h 

40 l/h 

40 l/h 

User-supplied connection with external thread as per DIN 44991 (flat sealing)

   

¾“

 

¾“

 

¾“

 

¾“

 

Connection hose 

½“ with screw fitting ¾“ 

 

 

 

 

 

Connecting hose, length 

 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

 

 

 

 

 

 

Hot water (WW)

 

 

 

 

 

 

Max. inlet temperature 

 

158°F (70°C) 

158°F (70°C) 

158°F (70°C) 

158°F (70°C) 

Permissible water flow pressure 

 

100 

– 1000 kPa 

100 

– 1000 kPa 

100 

– 1000 kPa 

100 

– 1000 kPa 

Required volume flow 

 

11 l/min 

11 l/min 

11 l/min 

11 l/min 

Average water consumption (60°C standard program) 

 

13 l/h 

13 l/h 

13 l/h 

13 l/h 

User-supplied connection with external thread (flat sealing)

 

 

¾“

 

¾“

 

¾“

 

¾“

 

Connection hose 

½“ with screw fitting ¾“ 

 

 

 

 

 

Connecting hose, length 

 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

 

 

 

 

 

 

Service water (BW)

 

 

 

 

 

 

Kit with additional inlet valve 

 

 

 

 

 

Permissible water flow pressure 

 

100 

– 1000 kPa 

100 

– 1000 kPa 

100 

– 1000 kPa 

100 

– 1000 kPa 

Required volume flow 

 

11 l/min 

11 l/min 

11 l/min 

11 l/min 

Average water consumption (60°C standard program) 

 

14 l/h 

14 l/h 

17 l/h 

17 l/h 

User-supplied connection with external thread as per DIN 44991 (flat sealing)

   

¾“

 

¾“

 

¾“

 

¾“

 

Connection hose 

½“ with screw fitting ¾“ 

 

 

 

 

 

Connecting hose, length 

 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

5‘ 1“ (1550 mm) 

 

 

 

 

 

 

Drain valve (AV)

 

 

 

 

 

 

Connecting piece (external diameter) 

 

 

3“ (75 mm) (DN70)

 

-

 

3“ (75 mm) (DN70)

 

-

 

Max. waste water temperature 

 

194°F (90°C) 

 

194°F (90°C) 

 

Max. short-time flow volume 

 

62 l/min 

62 l /min 

 

 

 

 

 

 

Soap pump (LP)

 

 

 

 

 

 

Hose connector (external diameter)  

 

7/8“ (22 mm) 
(DN22) 

7/8“ (22 mm) 
(DN22) 

Max. waste water temperature 

 

194°F (90°C) 

194°F (90°C) 

Содержание PW 6055 AV

Страница 1: ...ion Plan Washing Machine PW 6055 AV LP PW 6065 AV LP Read all operation and installation instructions prior to assembly installation and initial operation to prevent injury and machine damage en US 10 145 220 01 ...

Страница 2: ... pump B Appliance fastening PA Equipotential bonding BW Service water connection SLA Peak load connection DOS Dosing unit connection UG Base closed EL Electrical connection UO Base open F Adjustable appliance mounts WTV Washer dryer connection KG Payment device WW Hot water connection KGA Payment device connection XKM Communication module Alteration rights reserved 08 14 155 ...

Страница 3: ...PW 6055 6065 en 10 145 220 01 3 Appliance Dimensions PW 6055 ...

Страница 4: ...en PW 6055 6065 4 10 145 220 01 Installation PW 6055 ...

Страница 5: ...PW 6055 6065 en 10 145 220 01 5 Washer Dryer Stack PW 6055 ...

Страница 6: ...en PW 6055 6065 6 10 145 220 01 Appliance Dimensions PW 6065 ...

Страница 7: ...PW 6055 6065 en 10 145 220 01 7 Installation PW 6065 ...

Страница 8: ...en PW 6055 6065 8 10 145 220 01 Washer Dryer Stack PW 6065 ...

Страница 9: ...PW 6055 6065 en 10 145 220 01 9 Assembly ...

Страница 10: ...en PW 6055 6065 10 10 145 220 01 Assembly ...

Страница 11: ...consumption 60 C standard program 36 l h 36 l h 40 l h 40 l h User supplied connection with external thread as per DIN 44991 flat sealing Connection hose with screw fitting Connecting hose length 5 1 1550 mm 5 1 1550 mm 5 1 1550 mm 5 1 1550 mm Hot water WW Max inlet temperature 158 F 70 C 158 F 70 C 158 F 70 C 158 F 70 C Permissible water flow pressure 100 1000 kPa 100 1000 kPa 100 1000 kPa 100 10...

Страница 12: ...l diameter x length 5 16 x 1 9 16 8 x 40 mm 5 16 x 1 9 16 8 x 40 mm 5 16 x 1 9 16 8 x 40 mm 5 16 x 1 9 16 8 x 40 mm Floor mounting Miele base Accessories for Miele base fasteners supplied with product Required fastening points Number 4 4 4 4 Wood screw as per DIN 571 5 16 x 2 9 16 8 x 65 mm 5 16 x 2 9 16 8 x 65 mm 5 16 x 2 9 16 8 x 65 mm 5 16 x 2 9 16 8 x 65 mm Dowel diameter x length x 2 3 8 12 x...

Страница 13: ... UG 5005 Base galvanized stainless steel side panels Base closed H 1 6 470 mm UG 5005 47 Base galvanized octoblue heat cure coated side panels Base closed H 2 5 750 mm UG 5005 75 Base galvanized octoblue heat cure coated side panels Base open UO Base open H 11 13 16 300 mm UO 5005 Base galvanized octoblue heat cure coated surface Base open H 1 6 470 mm UO 5005 Base galvanized octoblue heat cure co...

Страница 14: ...e such as timers must not be installed The conductor cross section information in the technical data refers only to the required connecting cable Refer to the applicable national and local regulations for calculating the other dimensions Cold water connection You may connect the washing machine to a drinking water system without a backflow preventer because it has been designed according to the ap...

Страница 15: ...ce for this function Alternatively you can use a wireless multi station system for maximum 8 terminals with a debit card payment device and additional controllers for terminal monitoring Serial interface The serial interface is provided with an additional integrated XKM RS323 module The data interface leading from the XKM RS232 module is compliant with SELV safety extra low voltage Any connected e...

Отзывы: