background image

 

 

 
 

Technical datasheet 

 

 
 

 

 

 

 

 

 

Tumble dryer:  
Heating: 
 

PT 8807 
Steam (D) 

 

 

Legend: 

 

Abbreviations in bold type:

 

Connection required 

en - US 

 

 

 

Abbreviations in circle with dashes:

 

Connection optional or required depending on model version 

 

Optional extras: 

BS 

Concrete base 

Quality and density of concrete must comply with load. 
Concrete base must be firmly secured to floor! 

 

 

Recommended height 

4“ 

100 mm 

Minimum height 

2“ 

50 mm 

 

 

Minimum width 

36“ 

900 mm  

 

 

Minimum depth 

48“ 

1200 mm 

DAV 

Steam 

connection 

valve 

The steam connection valve to regulate the steam supply 
must be provided on site. 

The following valves can be ordered separately as electric 
steam valves or as pneumatic steam valves. 

 

 

 

 

Pneumatic steam valve (PND) 

 

 

 

 

Regulatable steam pressure 

0 - 145 psi 

0 - 1000 kPa 

 

 

Connection gauge 

½“ 

 

 

 

Supply point and pneumatic valve controls must be provided on site.  

 

 

Machine connections: 

 

Electrical 

connection 

Voltage

  

 

3 AC 208 V 

 

Frequency 

 

60 Hz 

 

Rated load 

 

6487.4 BTU/h 

1.9 kW 

 

 

Fuse rating 

 

3 x 10 A 

 

 

 

Connection cable, min. cross-section 

 

4 x AWG 16 

4 x 1.5 mm² 

 

 

(Connection cable to be ordered separately) 

 

 

 

 

 

Electrical connection must comply with national regulations. 

Connection using multi-pole wall socket in compliance with IEC/EN 60309 and IEC/EN 60947 is 
recommended in order to simplify electrical tests. 

If machines are hard-wired, a multi-pole switch must be provided on site. 

A wall socket or isolator must be accessible after installation. 

 

 

 
 

 

Installation plan: PT 8807 D 

Date: 29-Jan-2015 

 

Page: 13 

Содержание PT 8807 D (Steam)

Страница 1: ...Installation Plan Tumble dryer PT 8807 D Steam en US 05 15 M Nr 10 126 430 ...

Страница 2: ...It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved M Nr 10 126 430 2 ...

Страница 3: ...PT 8807 D en US Machine dimensions measurements in inches 3 ...

Страница 4: ...en US PT 8807 D Machine connections measurements in inches 4 ...

Страница 5: ...PT 8807 D en US Machine connections measurements in inches 5 ...

Страница 6: ...en US PT 8807 D Standard installation measurements in inches 6 ...

Страница 7: ...PT 8807 D en US Option Installation on concrete platform BS measurements in inches 7 ...

Страница 8: ...en US PT 8807 D Machine dimensions measurements in millimeters 8 ...

Страница 9: ...PT 8807 D en US Machine connections measurements in millimeters 9 ...

Страница 10: ...en US PT 8807 D Machine connections measurements in millimeters 10 ...

Страница 11: ...PT 8807 D en US Standard installation measurements in millimeters 11 ...

Страница 12: ...en US PT 8807 D Option Installation on concrete platform BS measurements in millimeters 12 ...

Страница 13: ...eam valves or as pneumatic steam valves Pneumatic steam valve PND Regulatable steam pressure 0 145 psi 0 1000 kPa Connection gauge Supply point and pneumatic valve controls must be provided on site Machine connections Electrical connection Voltage 3 AC 208 V Frequency 60 Hz Rated load 6487 4 BTU h 1 9 kW Fuse rating 3 x 10 A Connection cable min cross section 4 x AWG 16 4 x 1 5 mm Connection cable...

Страница 14: ...ans no condensate is left in the heater element Installation of an inverted bucket steam trap is recommended Air outlet Max nominal air flow in vented mode 39200 cu ft h 1110 m h Max permissible pressure loss 6 3 psf 300 Pa Connection on machine side ext diameter 5 15 16 150 mm Connection pipe provided on site int diameter 5 15 16 150 mm Max temperature 176 F 80 C As relative humidity inside the v...

Страница 15: ...47 1 4 1200 mm Casing depth 50 3 8 1279 mm Minimum width of delivery access to installation site 48 1220 mm Recommended rear wall gap measured to front of machine 70 7 8 1800 mm Min wall gap to rear edge of lid 19 3 4 500 mm Net weight 701 1 lbs 318 kg Dynamic floor load max 834 lbf 3708 N Average heat dissipation depends on ambient room temperature and selected program 3692 BTU h 1082 W Noise lev...

Отзывы: