Installationsplan PT 7251 EL 
Stand: 23.09.2004 

 Seite 

 

 

 
 

Technical datasheet

 

 
 

 

 

 

 

Tumble dryer:

 

Heating: 
 

PT 7251 

Electric (EL) 

 

 Legend: 

 

Circled, bold-type abbreviations: 
Connection required 

 

 

 

Abbreviations surrounded by broken circle: 
Connection optional or required, depending on model 

G

 

 

Optional extras: 

Concrete plinth (to be provided on-site) optional. 

 

 

Min. concrete quality B15 

 

 

BS 

Concrete platform 

Recommended height 

mm 

50 

  

Minimum 

height 

mm 

50 

  

Recommended 

width 

mm 900 

  

Recommended 

depth 

mm 850 

 

 

Ensure good anchorage! 

 

 

 

Machine connections: 

1. Standard voltage (as supplied) 

 

3N AC 380-415  

Frequency  

Hz 

50 

(60) 

 

Electrical 

connection 

Rated load 

 

kW 

14.2 

 

 

Fuse rating 

 

3 × 25 

 

 

Supply lead (H 07 RN-F), min. cross-section 

 

mm² 

5 × 4 

 

 

with threaded cable connector 

 

 

M 32 

 

 

2. Standard voltage (as supplied) 

 

3 AC 220-240 

  

Frequency 

 

Hz 

50 

(60) 

  

Rated 

load 

 

kW 

14.2 

 

 

Fuse rating 

 

3 × 50 

 

 

Supply lead (H 07 RN-F), min. cross-section 

 

mm² 

4 × 10 

 

 

with threaded cable connector 

 

 

M 40 

 

 

3. Standard voltage (as supplied) 

 

3 AC 440 

  

Frequency 

 

Hz 

50 

(60) 

  

Rated 

load 

 

kW 

14.2 

 

 

Fuse rating 

 

3 × 25 

 

 

Supply lead (H 07 RN-F), min. cross-section 

 

mm² 

4 × 4 

 

 

with threaded cable connector 

 

 

M 32 

 

 

Connection using multi-pole wall socket in compliance with 
IEC 60309 and IEC 60947 is recommended in order to 
simplify electrical tests.  
If using a hard-wired connection, install mains isolator 
according to IEC 60947. 
Wall socket or mains isolator must be accessible after 
installation. 
The use of an earth leakage circuit breaker (ELCB) is strongly 
recommended. 
If necessary, equipotential bonding with good galvanic contact 
must be provided in accordance with all appropriate national 
and local regulations. 

 

 

Connection cable, min. cross-section 

mm² 

3 × 1.5 

Peak load  

management 

Input leads should not be in direct contact with any source of 
heat. 

 

 

 

 

Signal supplied via potential-free (galvanically separated) 
contact. 

 

 