manualshive.com logo in svg
background image

Operating and Installation manual

Vented Dryer
PT 7136 Plus

To prevent accidents
and machine damage
read these instructions

before

installation or use.

UV

M.-Nr. 06 855 790

Содержание PT 7136 Plus

Страница 1: ...Operating and Installation manual Vented Dryer PT 7136 Plus To prevent accidents and machine damage read these instructions before installation or use UV M Nr 06 855 790 ...

Страница 2: ... 22 Cleaning the exterior and the control panel 24 Frequently asked questions 25 After sales service 31 Optional accessories 31 INSTALLATION INSTRUCTIONS 33 Installation 34 Electrical connection 39 Installation of exhaust venting 40 General notes 40 How to calculate the effective duct length 41 Determining the position of the exhaust connection 44 Exhaust connection with a flexible exhaust hose or...

Страница 3: ... the machine and an effective grounding system which complies with local and national regulations It is imperative that this basic safety requirement be met If there is any doubt have the electrical system of the house checked by a qualified technician The manufacturer cannot be held responsible for damage which is the direct or indirect result of incorrect installation or connection Do not connec...

Страница 4: ... another appliance which also uses the room air e g gas oil or coal fired heater continuous flow or other water heater is installed in the same or an adjacent room Allow sufficient room ventilation by unlockable ventilation openings in the wall Check with your building inspector for a riskless use to avoid a low pressure of 4 Pa or more Never connect an exhaust duct to an active chimney vent flue ...

Страница 5: ... a special detergent Contact the detergent manufacturer Do not lean on the door The dryer may tip over Always close the door after use to prevent hazards For example children trying to climb into the dryer or hide items in it small pets climbing into the dryer To protect the machine from rust only use chloride free cleaning and disinfecting agents Chloride may cause corrosion Do not store chloride...

Страница 6: ...n also save a Favorite drying program on these buttons c Start button d Optical interface PC Allows a service technician to check and update the drying programs e Jog shuttle Turn to select menus Press to confirm the selection f a button To open the drum door Contents in the display will vary with program offering Guide to the dryer 6 ...

Страница 7: ...uttons The first four programs shown in the display on the left are the Favorites They can be selected with the direct select buttons The Favorites can be individually set to your desire See Favorites for more information The direct select buttons have different functions in the other menus In these menus an arrow H is displayed above the respective button with the function description of the butt...

Страница 8: ...selected program Basic menu of a drying program Cottons Normal Duration 1 16 h Low temp H Timer Y H Save H Back A H The Drying level or Program can be selected by turning the jog shuttle The selected component is highlighted Press the jog shuttle to select or adjust the component Select Low temp or Timer by pressing D E Press G to get back to the Basic menu All components can also be selected and ...

Страница 9: ...rst time The welcome screen will not show anymore when the total use time of the dryer exceeds one hour The display then shows the language selection Language J Select the desired language and confirm with OK Set the time of day Set the hour by turning the jog shuttle and press to confirm Repeat to set the minutes and confirm Press again to save the time of day Before using for the first time 9 ...

Страница 10: ...lored items before drying for the first time and do not dry with light colored items These fabrics can bleed also on plastic parts of the dryer Colored fluff may also get on the light colored items Wool and wool blends tend to felt and shrink Dry wool and wool blends in the Woollen handcare program The fine fabric of down filled items tend to shrink Dry these items in the Smoothing program Dry pur...

Страница 11: ...mall items from getting trapped inside of them Close zippers hooks and eyelets Tie fabric belts and apron ties Remove or sew up released bra underwires 2 Load the laundry Use the a button to open the drum door Load the laundry loosely into the drum Do not overload the drum Overloading strains the fabrics and results in poor drying results To prevent fabric damage check that laundry is not caught i...

Страница 12: ...ard the displayed request to pay If the door is opened after a program has started or if the program is canceled the credit is lost 6 Starting a program Start flashes when a program can be started Press the Start button The Start button lights The display shows Programme start and then Drying with the program duration The drying levels of the drying level programs are displayed e g machine iron ha...

Страница 13: ... end of a program After drying with hot air the cool down phase finishes the program Cooling down is displayed Only after the cooling down phase has ended the program is finished These programs do not have a cooling down phase Woollen handcare Smoothing 7 At the end of a program Anti crease if selected and End mark the end of a program in the display During the anti crease phase the drum will turn...

Страница 14: ...el once more and End is displayed Press the a button Open and close the door Select the new program Press the Start button Adding removing laundry during a drying program Press the a button Open the door Do not touch the rear of the drum while adding or removing items Danger of burns due to high temperatures in the drum Add or remove items Close the door Continue drying Press the Start button Note...

Страница 15: ...d iron rr Machine iron Items Cotton or linen fabrics to be left damp for easier ironing e g table cloths bed linen starched laundry etc Note Select Low temp for items with the fabric care symbol r Roll up items until they are ironed to keep them moist Minimum iron Load size 7 7 lbs 3 5 kg Normal Normal Hand iron r Items Permanent Press items of cotton mixed fabrics or synthetics e g sweaters dress...

Страница 16: ...te Program to reduce creasing after previous spinning in the washer Remove the items immediately after the program end and allow to air dry Cool air Load size 14 3 lbs 6 5 kg Items To air items Warm air Load size 14 3 lbs 6 5 kg Items Final drying of multi layer fabrics with unique drying characteristics e g jackets pillows and large textiles Drying of single items beach towels bathing suits etc N...

Страница 17: ...5 5 lbs 2 5 kg Items For dryer suitable items e g ski and outdoor clothing table cloths and poplin items Note This program has an additional step for the water proofing Water proofed items must only be treated with a water repellant that is Suitable for membrane textiles These chemicals are based on flourochemicals Do not dry items which were treated with agents containing paraffin This is a fire ...

Страница 18: ...Start 10 13 Finish 12 00 Select the desired program end time with the jog shuttle and confirm The program end time is adjusted to the next full or half hour The program start will be delayed in accordance with the desired program end time Starting the delay start function Press the Start button The elapsed time is displayed and will count down in minutes The drum turns briefly every hour to preven...

Страница 19: ...ecting Changing a Favorite Close the door Main menu 1 Cottons Programme selection 2 Minimum iron Settings F 3 Woollens handcare 4 Smoothing 10 00 Press the D button Basic menu Cottons Normal Duration 1 16 h Low temp H Timer Y H Save H Back A H Turn the jog shuttle to select the component you want to adjust program Cottons or the drying level Normal Press the jog shuttle to confirm the selection Fa...

Страница 20: ...conds Drying level programs Cottons Normal Drying levels from c Machine iron Extra dry Select and confirm the desired drying level with the jog shuttle The display shows the drying level range of each program Program Warm air Cool air Warm air 0 30 h 10 00 Finish 10 30 Duration 0 30 h The duration can be extended or shortened with the jog shuttle maximum 2 hr cold air 1 hr warm air The program end...

Страница 21: ...ttons Normal Low temp Duration 1 47 h Low temp B H Timer Y H Save H Back A H Press the F Save button Assigning a direct select button Cottons Normal Low temp Previous Cottons Normal Save to 1 2 3 4 Back A Select the desired number for the favorite with the jog shuttle and confirm The favorite is saved with the individual selections and shown in the main menu To assign more favorites repeat the pro...

Страница 22: ...he lint It has to be removed and disassembled Note Use a vacuum cleaner to clean the lint filter without touching it Removing the lint filter Press on the right side of the flap to open it Pull the lint filter out by its handle Disassembling the lint filter Hold the lint filter with both handles and twist the inner filter towards you then pull apart see illustration Cleaning and Care 22 ...

Страница 23: ...dryer efficiency can be affected by wet lint filters Cleaning the fan cavity Check the fan cavity regularly Clean only if heavily soiled Open the door Turn the knobs a of the left and right covers until they click Holding by the knobs pull the covers up b and clean Use a vacuum cleaner to clean the lint filter Insert the covers and lock them in place by turning the knobs until they click Cleaning ...

Страница 24: ...y be turned so that the filter can be conveniently inserted removed Close the lint filter flap Cleaning the exterior and the control panel To reduce the risk of electric shock disconnect this appliance from the power supply by unplugging or tripping the circuit breaker Do not use an abrasive cleaner a glass cleaner or an all purpose cleaner They will damage the dryer Do not hose the dryer down The...

Страница 25: ... load This is not a fault The electronic notes that no laundry is in the drum and cancels the program Single items or already dried laundry can also cause a program stop Single items should be dried with a Timed drying program To delete the message Open the door Technical fault A numerical fault message shows e g F47 The fault cannot be detected immediately In some cases Clean out airways is displ...

Страница 26: ...fficiently Possible cause clogging by lint or detergent residues Check all possibilities as described under The program runs too long or stops To delete this message Confirm with OK The exhaust duct maybe very long This is not a fault With a long exhaust duct program times and energy consumption increase The cycle of the Clean out airways message can be adjusted See Settings Supervisor level Clean...

Страница 27: ...vent bends etc for air permeability Remove the lint The laundry was not spun sufficiently in the washer Spin laundry thoroughly before drying The dryer is over loaded Regard the maximum load size per program Metallic zippers prevent a correct measurement of the laundry s residual moistness Open the zippers of the laundry before drying If the problem persists dry the items with long zippers only in...

Страница 28: ... synthetic fabrics have static cling after drying Synthetics are prone to static cling Use liquid fabric softener in the last rinse of the wash to minimize the static cling during drying Lint has built up Lint is the result of friction caused by items being worn and washed This lint is loosened during drying It has been established by research institutes that dryers have no detrimental effects on ...

Страница 29: ...ected under Settings Language J Select the desired language The flag symbol leads you to the setting The Start indicator flashes when selecting a program This is not a fault It indicates that the program can be started After the program is started the indicator lights steadily The display is dark the ring of light around the jog shuttle does not light The Start indicator flashes slowly The display...

Страница 30: ...d twist see illustration Flip down the bulb cover Replace the light bulb with a temperature proof bulb available from Miele The light bulb must not exceed the maximum wattage quoted on the data plate Replace the light bulb with a new one Flip the light bulb cover upwards and press it firmly onto the left and right side until it clicks into place Make sure the bulb cover is securely closed to preve...

Страница 31: ...and serial number of your appliance They can be found on the data plate located below the drum opening The PC indicator allows a service technician to check and update the drying programs The update allows future developments of fabrics detergents and drying programs to be incorporated into the machine s electronic control Optional accessories Optional accessories are available from Miele After sa...

Страница 32: ...32 ...

Страница 33: ...Installation Instructions To prevent accidents and machine damage read these instructions before installation or use ...

Страница 34: ...se can be installed either at the rear left or right of the dryer b Power cord c Control panel d Door e Lint filter flap f Four height adjustable feet g Stand h Optional accessory retaining clips use when installed on a cement base Installation 34 ...

Страница 35: ...Side view Rear view a Lid over hang with transport grips arrow b Stand Optional accessory Installation 35 ...

Страница 36: ...r can be installed as part of a washer dryer stack in combination with a Miele washer An appropriate stacking kit available from Miele is required Installation of the stacking kit must be completed by a Miele Service Technician Installation 36 ...

Страница 37: ...chanism The dryer can be equipped with a coin mechanism optional accessory Miele s Technical Service will install the coin mechanism and program the dryer electronic Empty the coin mechanism regularly to avoid the coins getting jammed Do not install devices to automatically turn the dryer off e g clock timers Installation 37 ...

Страница 38: ...transport the dryer from the packaging base to the installation site Level the dryer The dryer must be level to ensure safe and proper operation The machine can be leveled by turning the legs clockwise or counterclockwise as necessary An air gap of 3 8 10 mm must be provided between the machine and the floor The vents must not be blocked by toe kicks long piled carpet etc This dryer cannot be inst...

Страница 39: ...rrent of 30 mA If the machine is hard wired three 20 A circuit breakers must be provided on site Switches with a contact gap of more than 1 8 3 mm are valid as separators All components have to bear CSA or UL approval The machine must only be connected to the voltage and frequency shown on the data plate To convert the machine to another electrical connection please read the conversion manual on t...

Страница 40: ... exhaust connection e g a wall pipe must be installed so that the moist exhaust air cannot get drawn back into the installation room and cause constructional damage or unreasonable disturbance Provide sufficient venting in the room where the dryer is installed by opening a window or installing unlockable ventilation openings in the wall Danger of suffocation by suction of exhaust fumes Installatio...

Страница 41: ... the necessary duct diameter is not employed Tips about the ductwork Check with your local building code to determine the maximum allowable duct length Use a flexible metal pipe or rigid a metal pipe for venting Non metallic flexible hose should not be used it is a potential fire hazard Use the wall vent or window connection optional accessories for venting outdoors For optimal drying results avoi...

Страница 42: ...e 90 angle 10 10 25 25 5 11 4 11 8 2 180 150 250 Smooth metal duct 3 3 1 m straight 45 angle 90 angle 10 10 25 25 3 3 1 11 2 7 100 60 80 Elbow 90 sharp 7 6 230 Concertina bend 90 angle 8 20 2 4 70 Wall vent or window vent with louvers with flap 12 5 4 11 380 150 Exhaust connection left or right side 3 3 100 Installation of exhaust venting 42 ...

Страница 43: ... m A Wall duct with louvered wall vent 12 5 3 8 m B 90 bend 2 7 0 8 m C 20 0 5 m rigid pipe 1 7 0 5 m D 90 bend 2 7 0 8 m E left vent opening 3 3 1 0 m Total duct length 22 5 6 9 m The total duct length is less than 33 feet 10 m so a duct diameter of 4 100 mm with adapter is sufficient Installation of exhaust venting 43 ...

Страница 44: ...ar of the dryer factory standard or moved to the left or right side of the dryer Changing the position of the exhaust connection Remove the cap turning it counterclockwise Press the supplied cover firmly into the rear opening Install the exhaust duct as follows Installation of exhaust venting 44 ...

Страница 45: ...ional accessory an exhaust hose made of approved non flammable material rigid pipe is more suitable for long ducts less friction Install the connector 1 with the exhaust hose or pipe 2 to the dryer Window connection 1 Window connection installed in a plexiglass pane 2 Connector for the flexible exhaust hose Wall connection with rigid pipe 1 Wall pipe 2 Connector 3 Rigid pipe Installation of exhaus...

Страница 46: ... wall pipe 2 Connector for the flexible exhaust hose 3 Chimney humidity insulated The appliance must not be connected to a chimney or vent flue which is in use Neither should it be connected to ducting which ventilates rooms with fireplaces Installation of exhaust venting 46 ...

Страница 47: ...r will be However for the wall pipe to be installed a hole must be cut through the outer wall Regard the Install manual for the Miele wall pipe and the dimension illustrations below Necessary materials wall pipe optional accessory a flexible spacer ring optional accessory Dryer top view 1 Wall pipe 2 Flexible foam gasket space ring Installation of exhaust venting 47 ...

Страница 48: ...Dryer side view 1 Wall pipe 2 Flexible foam gasket space ring Connect the flexible space ring 2 to the wall pipe connector 1 Push the dryer to the wall Installation of exhaust venting 48 ...

Страница 49: ...ers can be damaged and the electrical safety compromised When installing multiple dryers increase the duct diameter Amount of units Increasing factor for duct diameter from table 2 2 3 4 max 5 1 1 25 1 5 1 Connection to collecting duct 2 Non return flap 3 Additional adapter 4 Vent hose Push the non return flap 2 into the adapter 3 Installation of exhaust venting 49 ...

Страница 50: ...rum 28 6 gal 130 l Maximal load 14 3 lbs 6 5 kg Dry laundry weight Power cord 63 1 600 mm Fuse rating see data plate Rated load see data plate Fuse rating see data plate Light load see data plate Testing approvals Radio TV Suppression VDE in Germany Maximum floor pressure during operation approx 159 lbs 72 kg Noise level 70 dB A Technical Data 50 ...

Страница 51: ...tic wrappings bags etc are disposed of safely and kept out of the reach of children Disposal of an appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Ensure that a discarded dryer presents no danger to children While being stored for disposal remove the door to the drying compartment C...

Страница 52: ......

Страница 53: ...ettings Depending on the programming status of the machine some settings may be visible and can be changed by all users Menu Settings J or all settings under the supervisor level can be locked with a code to prevent unauthorized access Menu Settings Supervisor level Contact Technical Service for more information ...

Страница 54: ... and confirm by pressing the jog shuttle Selecting Settings Settings Back A Language F Anti crease Buzzer H Select the settings to be changed and confirm If no selection was made in the sub menu the display will switch back to the Settings menu after 20 seconds Leaving the Settings menu Press Back and confirm The display shows the main menu Settings J 54 ...

Страница 55: ...removed Default setting on Buzzer When the buzzer is selected a tone sounds at the end of a program Off The end of program buzzer is turned off However it does not turn off the warning tone which indicates a fault message normal The buzzer sounds normal at the end of a program factory default loud The buzzer sounds loud at the end of a program Time of day The selection allows the clock to be shown...

Страница 56: ... not during current program factory default The Standby is turned on when no program is selected Pressing any button or turning the jog shuttle turns the display on again Lengthening the cooling time The cooling phase can be lengthened before the program is started The laundry will be cooled The bar shows the selected level Delivery status 0 minutes normal cooling down phase The program duration i...

Страница 57: ...via code Select Access via code and confirm Entering the code Enter the code 0 0 0 factory default If a wrong code is entered three times the code entry will be locked for 1 hour 0 _ _ Please enter code Turn the jog shuttle until the first digit shows Confirm the digit Enter the second and third digits 0 0 0 Please confirm code OK H Back A H Confirm the code Settings Supervisor level 57 ...

Страница 58: ... be shown in the main menu The function Save is needed to save for example the favorite drying programs on the direct select buttons The machine comes factory set with this option turned off Drying levels The bars show the selected level Factory default medium level The program duration shortens more moist or lengthens more dry Drying level Cottons and Minimum iron The drying level of Cottons or M...

Страница 59: ...t is collected Cleaning the lint filters The display Clean filter reminds the user to clean the lint filter The user can decide after how many operating hours this reminder should show The setting depends on the lint amount Adjust the interval depending on the use of the dryer Factory default after 20 hours Display Residual moisture in percent In addition to the drying levels the residual moisture...

Страница 60: ...All rights reserved 1406 M Nr 06 855 790 00 en USA ...

Отзывы: