Operation
41
Refilling or changing containers
The DOS module is equipped with a
level indicator.
Refill detergent
will appear
in the display when the level drops be-
low the minimum.
As soon as the message appears in
the display, refill or replace the con-
tainer with a full one at the end of the
programme.
Confirm the message shown with the
OK
button.
Replace the container in good time
to prevent the dispensing system be-
ing emptied completely.
An empty dispensing system must
be vented before starting the next
programme.
Place the container on the open cab-
inet door or on a surface which is
easy to clean.
Unscrew and remove the siphon.
Place the siphon on the open cabinet
door.
Replace the empty container with a
full one.
Push the siphon into the opening of
the container and screw it on tightly.
Observe the colour coding.
Wipe up any spilled process chemical
thoroughly.
Place the container on the floor be-
side the dishwasher or in an adjacent
cupboard. The container must be at
the same level as the machine and
not be placed on top of or above the
machine.
The dispensing system must then be
vented.
To vent the system and adjust the
dosage amount, see
“Settings menu, External dispens-
ing”.
Checking consumption
Monitor the amount of chemical agents
used by regularly checking the level in
the container.