Supervisor level
87
Peak load signal
External hardware is connected via the
Miele XCI box.
The peak-load negotiation function
enables the tumble dryer to be con-
nected to an energy management sys-
tem. When a signal is registered, the
tumble dryer's heater is switched off
for a short period or the appliance is
prevented from being switched on.
The tumble dryer may only be oper-
ated with a peak-load system if this
system is connected to the tumble
dryer via the Miele XCI box.
– Factory default: no function
– Peak load with 230 V
– Peak load with 0 V
Peak load prevention
With this function, the application of a
hygiene programme is not amended
when a peak load signal is in place.
The heater stays switched on.
– Factory default: Off
– On
Payment system
External hardware is connected via the
Miele XCI box.
Setting for payment systems
If you wish to change the settings after
the commissioning process, please
contact Miele Service.
You would like to connect a payment
system.
– No payment system
The next settings are skipped and ini-
tial commissioning can be com-
pleted.
– Programme operation
The machine is operated using a coin
box. The user purchases a wash pro-
gramme.
– Timed operation
The tumble dryer is coin-operated
using a time meter. The user pur-
chases a time-controlled programme.
– Timed operation with pulse counter
For payment systems where the us-
age time is increased each time a
coin is inserted.