Technical Information
W1900 Series Clothes Washers
5.5
Air Trap – Replacement
Refer to Figure 5-4 – Air Trap and Level Switch Components.
1. Open the Front Service Panel – Refer to Section 5.3.
2. Manually drain all remaining water – Refer to Section 5.8.
3. Pull the Air Trap (item 3) outward to remove from the appliance.
4. Remove the Air Hose (item 2).
5. Remove the Seal.
Re-Installation
1. Install the new Seal.
2. Install the new Air Hose.
1 – Level Switch
2 – Air Hose
3 – Air Trap
Figure 5-4:
Air Trap and Level Switch Components
Important!
Ensure the Air Hose is:
Routed correctly
NOT being pinched by any of the retaining clips
NOT resting against any edge of the appliance frame
Service Tip:
The lug on the Air Trap must engage in the corresponding opening.