Technical Information
W1900 Series Clothes Washers
4.8
Water Control System – Rinses
During the rinse segment of the program if Level 1 is not reached within
90 seconds of water intake; the rinse duration is extended from 4.5 to 6.5
minutes by the Electronic.
4.9
Inlet Hose(s) Filters
The Water Inlet Hoses are equipped with two filters to protect the Water
Valves. One filter is fitted at the end of the hose (directly at the water
connection). The second filter is fitted within the threaded connections (on
the rear of the washer).
4.10
Inlet Valves
All washers (except the W1903) are equipped with a single Electro-
Mechanical Water Valve; to control hot water entering the appliance.
The cold water supply to the washer is controlled via a Triple Valve
Assembly. Although the component is physically one item; each valve is
plumbed (and electrically energized) separate to provide water control for
the:
x
Pre-Wash
x
Main-Wash
x
Rinse
4.11
Dispenser Assembly
The Dispenser Assembly distributes the incoming water to separate
compartments within the Dispenser Drawer.
Figure 4-4:
Dispenser Assembly
30