Gas connection
54
The gas connection must be made in
accordance with local codes or, in
the absence of local codes, with:
National Fuel Gas Code
ANSI Z 223.1 / NFPA No. 54 for the
United States or the current Can /
CGA B 149.1 and 2 Installation
Codes of Gas Appliances for
Canada.
The gas pressure may not under-
shoot or exceed certain values.
Make sure that the maximum gas
pressure upstream of the gas pres-
sure controller does not amount to
more than 1/2 psi (3.5 kPA) for natu-
ral and propane gas.
Make sure that the minimum gas
pressure amounts to a 6“ water head
in the case of natural gas and a
11” (279.4 mm) water head in the
case of propane gas.
The gas connection of the rangetop is
designed for natural gas or propane gas
according to the ordered model.
If the rangetop is not equipped with the
correct connection for the gas type in
your household, contact your Miele
dealer.