Exhaust ducting
83
If the cooker hood is used at the
same time as a heating appliance
that relies on oxygen from the same
room, there is a risk of toxic fumes.
It is essential that the "Warning and
Safety" instructions are observed.
The cooker hood should be installed
according to local and national
building regulations. Seek approval
from the building inspector where
necessary.
The cooker hood has an exhaust
connection of 222 x 89 mm.
Use smooth pipes or flexible ducting
made from approved non-flammable
materials for exhaust ducting.
To achieve the most efficient air
extraction with the lowest noise
levels, please note the following:
– The cross-section of the exhaust
ducting must not be smaller than the
cross-section of the exhaust
connection (see "Appliance
dimensions").
– The exhaust ducting should be as
short and straight as possible.
– Only use wide radius bends.
– The exhaust ducting must not be
kinked or compressed.
– Ensure that all connections are
strong and airtight.
Remember that any constriction of
the air flow will reduce extraction
performance and increase operating
noise.
If the exhaust air is to be ducted into
a flue, the ducting must be directed in
the flow direction of the flue.
Where ducting is horizontal, it must
be laid to slope away at at least 1 cm
per metre. This is to ensure that
condensate cannot drain back into
the cooker hood.
If the exhaust ducting is to run
through rooms, ceiling space etc.
where there may be great variations
in temperature between the different
areas. The problem of condensation
will need to be addressed. The
exhaust ducting will need to be
suitably insulated.
Содержание KMDA 7774
Страница 65: ...Installation notes 65 Installation examples Recirculation mode Extraction mode ...
Страница 71: ...Building in dimensions Onset hobs 71 Extraction to the rear Extraction to the right Extraction to the left ...
Страница 73: ...Building in dimensions Onset hobs 73 Extraction to the rear Extraction to the right Extraction to the left ...
Страница 76: ...Building in dimensions Flush fit hobs 76 Extraction to the rear Extraction to the right Extraction to the left ...
Страница 78: ...Building in dimensions Flush fit hobs 78 Extraction to the rear Extraction to the right Extraction to the left ...
Страница 89: ......
Страница 90: ......
Страница 92: ...M Nr 10 797 991 00 en AE SA KMDA 7774 ...