
Safety distances underneath the hob
To ensure sufficient ventilation to the
hob, a minimum gap must be left
between the underside of the hob and
any oven, interim shelf or drawer.
The minimum gap between the
underside of the hob and
– the top of an
oven
is
15 mm
.
– the top of an
interim shelf
is
15 mm
.
– the base of a
drawer
must be
75 mm
.
Interim shelf
It is not necessary to fit an interim shelf
underneath the hob, but one may be
fitted if you wish.
A ventilation gap of 10 mm at the back
of the hob is necessary to
accommodate the cabling.
We recommend a ventilation gap at the
front of the hob of 20 mm to ensure
good ventilation.
Safety instructions for installation
63
Содержание KM 6350
Страница 8: ...Control panel Guide to the appliance 8 ...
Страница 81: ...81 ...
Страница 82: ...82 ...
Страница 83: ...83 ...
Страница 84: ...Alteration rights reserved 4911 M Nr 07 799 000 07 ...