Installation above an oven
a
Ventilation gap for the fan
when installed in a base unit without
a back panel.
When installed above a Miele oven
in a worktop thickness
0
40 mm
the
minimum ventilation gap for the fan
of 15 mm is present.
If the worktop is
ß
40 mm
, a filler
panel will have to be fitted above the
oven.
b
Top of oven
c
Induction hob fan
d
Distance between the front edge of
the fan and the worktop cut-out
(depending on the type of hob)
If the hob is installed in an island or in a
unit with an enclosed back panel, the
above measurements apply to a total
depth
0
800 mm. If the total depth is
less than 800 mm, then a minimum gap
of 100 mm must be provided for
ventilating the fan. In this case it is
advisable to fit a fixed drawer panel.
Installation
47