Safety distance when installing the appliance near a wall with additional
niche cladding
There must be a minimum distance of 50 mm between the niche cladding and the
worktop cut-out.
This distance is only necessary for niche cladding made of wood or any other
combustible material. For non-combustible materials (metal, ceramic tiles or
similar), this dimension can be reduced by the thickness of the niche cladding
material. The materials can warp or distort when subjected to high temperatures.
Flush-fitted hobs
Hob with frame or bevelled edge
a
Masonry
b
Niche cladding
c
Backmould
d
Worktop
e
Worktop cut-out
f
Minimum distance of 50 mm
Installation
35