![Miele KM 404 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/miele/km-404/km-404_installation-instructions-manual_234291017.webp)
Dimensions 7 mm and 11 mm are the
space taken up by the frame of the
appliance on the worktop.
^
Make a cut-out for the hob in the
worktop.
Dimension "B" applies to a combination
of appliances and is shown on the
chart.
^
There must be a minimum safety
distance of 50 mm between the hob
and the back wall and 200 mm
distance from a side wall to the right
or left of the hob. (See "Warning and
safety instructions").
^
Seal the cut surfaces with a suitable
sealant to avoid swelling caused by
moisture.
The materials used must be heat
resistant.
Worktop cut-out KM 414 / 417
Depth in mm
± 1 mm
Width (= Dim. B)
in mm
± 1 mm
1 hob
500
552-560
Worktop cut-out KM 414 / 417 +
288 mm wide appliances
Number
of
appliances
Depth
in mm
± 1 mm
Width
(= Dim. B)
in mm
± 1 mm
KM 414/417 + 1
KM 414/417 + 2
KM 414/417 + 3
KM 414/417 + 4
500
500
500
500
840
1 128
1 416
1 704
Important:
The maximum tolerance for the worktop
cut-out must not exceed ± 1 mm.
When building in several hobs a
spacer bar must be fitted between
each unit. See "Fitting spacer bars
and support brackets".
Narrow combiset appliances (288 mm
wide) can be installed to the left or right
hand side of the KM 414 / KM 417.
Worktop cut-out KM 414 / KM 417
17
Содержание KM 404
Страница 8: ...KM 404 aSupport bracket bBuilding in height plus 3 mm for fixing screw Appliance dimensions 8 ...
Страница 10: ...KM 406 aSupport bracket bBuilding in height plus 3 mm for fixing screw Appliance dimensions 10 ...
Страница 11: ...KM 414 aSupport bracket bBuilding in height plus 3 mm for fixing screw Appliance dimensions 11 ...
Страница 39: ...39 ...
Страница 40: ...Alteration rights reserved 1208 M Nr 04 930 603 10 ...