Converting to another gas type
*
I
N
S
T
A
L
L
A
T
I
O
N
*
53
Risk of explosion due to an in-
correct conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an approved and registered gas in-
staller in strict accordance with cur-
rent local and national safety and
building regulations (GasSafe in the
UK). The installer is responsible for
ensuring that the appliance functions
correctly when installed.
When converting to another type of
gas, both the main
and
small jets
need to be changed.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Main jet
Small jet
Natural gas H
Small burner
Medium burner
Large burner
Wok burner
0.76
0.94
1.20
2x 1.07 / 0.72
0.39
0.42
0.54
0.42
Liquid gas
Small burner
Medium burner
Large burner
Wok burner
0.52
0.66
0.81
2x 0.70 / 0.46
0.23
0.36
0.42
0.25
Changing the jets
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
Changing the main jets
Small, medium and large burners
Remove the pan support, burner
cap
and burner head
.
Using an M7 socket spanner, un-
screw the main jet
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.