Loosen the panel at the rear.
Depending on model, when doing
this, also loosen the connector plugs
for the hob.
^
Remove the side panel on the right.
The catalyser connection cables, lo-
cated near the vent duct, are now
easily accessible.
The vent duct for the ventilation system
is held in place by a coil spring.
^
Pull the coil spring to one side so that
the vent duct can be removed.
^
Remove the vent duct and its retain-
ing bracket.
The screws on the oven interior roof
must be loosened, before the vapour
outlet can be removed.
Service engineer fitting instructions