Installation -  extraction

Connection for extraction

Danger of toxic fumes.
Please heed the “Warning and
Safety instructions” to avoid the
danger of toxic fumes.

The cooker hood should be in-
stalled according to local building
regulations. Seek approval from the
building inspector where necessary.

Air extraction ducting 

– All ducting, pipework and fittings

must be of non-flammable material.

– The extraction ducting should be as

short and straight as possible.

To ensure efficient air extraction the
diameter of the exhaust ducting
should not be less than 150 mm.

If exhaust ducting with a diameter
of less than 150 mm or flat ducting
were to be used the noise level of
the cooker hood would increase
and extraction would be less effi-
cient.

– Only reduce the diameter of the duct-

ing if absolutely necessary, e.g.
where narrower ducting has already
been installed.

– Only use wide radius bends. Tight

bends reduce the air throughput of
the cooker hood.

– Only use smooth pipes or flexible

hoses made from non-flammable ma-
terials for extraction connection.

– When ducting is horizontal it must be

laid to slope away at

 

1 cm per metre,

to ensure no condensate drains into
the appliance.

– If the exhaust air is to be ducted into

the open air the installation of a tele-
scopic wall vent is recommended.

– If the exhaust air is to be ducted into

a vent flue the ducting must be di-
rected in the flow direction of the flue.

Important
If the exhaust ducting is to run
through rooms, ceiling space etc.,
where there may be great variations
in temperature between the different
areas, the problem of sweating or
condensation will need to be ad-
dressed.
The exhaust ducting will need to be
suitably insulated.

Installation -  extraction

30

Содержание Imperial DWA 950-2 EX

Страница 1: ...Operating and Installation Instructions Cooker Hoods DWF 956 2 DWF 956 EX DWF 950 2 DWF 950 EX Q ...

Страница 2: ...ours counter 12 Altering the filter operating hours counter 13 Cleaning and care Housing 14 Grease filters 14 Changing a halogen light bulb 16 After sales service 17 Electrical connection 18 Installation 20 Appliance dimensions 20 Fitting dimensions 21 Installation Retaining plates 22 Vapour canopy 24 Motor unit 25 Control unit 26 Preparation for extraction 27 Telescopic extension piece 28 Fitting...

Страница 3: ...als away please ensure they are of fered for recycling Disposal of your old appliance Old appliances contain materials which can be reclaimed or recycled Please contact your dealer your waste collec tion centre or scrap merchant about potential recycling schemes Ensure that the appliance presents no danger to children while being stored for disposal See the appropriate section in the Warning and S...

Страница 4: ...Guide to the appliance Guide to the appliance 4 ...

Страница 5: ...trol is used to show how long the grease filter has been in use see section on Operation Filter operating hours counter together with the run on option touch control to alter the number of hours counted by the filter operating hours counter see section Operation Al tering the filter operating hours counter k No function allocated to this touch control l Lighting touch control This control is used ...

Страница 6: ...s switched off No exchange of room air and outside air can take place When the cooker hood is switched on the non return flap opens for the cooking smells to be blown di rectly outside with an external fan The EX models are designed to be con nected to an external fan located out side the room The external fan is connected to the cooker hood by a control cable and is operated by the control panel ...

Страница 7: ...electrician The electrical safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations It is most import ant that this basic safety requirement is tested by a qualified electrician The manufacturer cannot be held re sponsible for the consequences of an inadequate earthing syst...

Страница 8: ...its smooth oper ation Clean or change the filter regularly An over greasy filter is a fire ha zard Under no circumstances use a steam cleaner to clean this ap pliance Pressurised steam could reach the electrical components and cause a short circuit Installation The distance between the top of the cooker hob and the bottom of the cooker hood must measure at least 45 cm above electric cookers hobs 6...

Страница 9: ...ac count If in any doubt the advice of a compe tent builder or for gas a Corgi instal ler must be sought In countries where there are areas which may be subject to infesta tion by cockroaches or other vermin pay particular attention to keeping the appliance and its surroundings in a clean condition at all times Any dam age which might be caused by cock roaches or other vermin will not be covered b...

Страница 10: ...od with a strong aroma the highest level marked IS Intensive Setting is recommended Use the power level touch control to select the power level required Touch control higher setting Touch control lower setting The indicator lamps show which power level has been chosen Run on option If the air still needs to be cleared after cooking the cooker hood can be set to continue running The fan motor will ...

Страница 11: ...se the On Off touch control to switch the fan off Switching the lighting on or off The lighting for illuminating the hob can be switched on or off independently of the fan Press the lighting touch control Operation 11 ...

Страница 12: ...must be re set To do this press the grease filter touch control and hold for about 4 seconds The indicator lamp will go out Reading the filter operating hours counter To check the percentage of the time set already used Use the On Off touch control to switch the fan on Press the grease filter touch control One or several of the indicator lamps above the power level touch control will flash The num...

Страница 13: ...ters and make cleaning more difficult Use the On Off touch control to switch the fan off Press the run on option touch control and the grease filter touch control at the same time The indicator lamp for the grease filter touch control and one of the lamps above the power level touch control will flash The power level touch control lamps show the time which has been set 1st lamp from left 20 hours ...

Страница 14: ...which scour or contain chlorine acids or soda These would damage the surface of the cooker hood Grease filters Re usable metal grease filters are fitted which remove solid particles oil dust etc from the kitchen vapours prevent ing soiling of the cooker hood The grease filters should be cleaned regularly to avoid a build up of fat ap prox 3 4 weeks on average but sooner if necessary Always clean t...

Страница 15: ...y After cleaning leave the filters to dry on an absorbent surface before put ting them back in place When removing the filters for clean ing also clean off any residues of oil or fat from the now accessible hous ing to prevent the risk of these catch ing fire After putting the grease filters back in place press the grease filter touch control for approx 4 seconds to re set the operating hours coun...

Страница 16: ... not touch im mediately as they remain hot for some time after being switched off You must not touch the surface of a halogen lamp when changing it as this will damage it Please follow the manufacturer s instructions To change the halogen lamp first remove the outer ring b Then detach the circlip c taking care that the cover d does not fall out The halogen lamp e is fitted to a push in connection ...

Страница 17: ...ept see address on back page When contacting the Service depart ment please quote the Model and Ser ial number of your appliance both of which are given on the data plate which is visible on removing the grease filter Please note that telephone calls may be monitored and recorded to improve our service After sales service 17 ...

Страница 18: ...ion must be provided for all poles For extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA in accordance with DIN VDE 0664 Important The wires in the mains lead are col oured in accordance with the following code Green yellow earth Blue neutral Brown live If the appliance is to be connected via a plug and socket please note the fol lowing As the colou...

Страница 19: ...and on no account be in serted into any socket elsewhere in the house electric shock hazard The fuse cover must be re fitted when changing the fuse and if the fuse cover is lost the plug must not be used until a suitable replacement is obtained The colour of the correct replacement cover is that of the coloured insert in the base of the plug as applicable to the design of plug fitted The correct f...

Страница 20: ... distance of 650 mm above elec tric cookers hobs may be prefer rable to give more working space See Warning and Safety instructions for further notes on safe installation Appliance dimensions H 770 1000 mm When venting to the rear through the wall the minimum height is 825 mm Maintain a minimum distance a be tween the top of the hood chimney and the ceiling of 2 cm so that the hood chimney can be ...

Страница 21: ...Fitting dimensions X Recommended height for fitting D Area for vent cut out E Area for socket and cable path for the connection cable with EX appliances Installation 21 ...

Страница 22: ... holes for attaching the vapour canopy and for fitting retaining plate A Mark the measurement X above the cooking surface This marks the height of the lower rim of the cooker hood Drill four 8 mm Ø holes in the wall as shown and press S8 plugs into the holes Screw retaining plate A to the wall with 5 x 40 mm screws through both holes and use the two notches to help you align it with the centre lin...

Страница 23: ...holes to be drilled on the wall Drill four 6 mm Ø holes into the wall and push the S6 plugs into the holes Screw on the retaining plate with four 4 x 30 mm screws and four 4 3 mm washers Retaining plate C Retaining plate C only needs to be fitted if dimension Y is greater than 400 mm It provides greater stability for the extension piece Hold the retaining plate C at a maxi mum distance of 400 mm f...

Страница 24: ...ning and care Hang the vapour canopy on to the angle brackets and the two screws on the retaining plate Tighten the two screws Also screw the two 5 x 40 mm screws through the holes provided in the vapour canopy from inside Cover the holes in the vapour ca nopy with the cover caps supplied Installation 24 ...

Страница 25: ... using 3 5 x 9 5 screws Non EXT models cooker hood are de signed to take 150 mm ø exhaust duct ing If 125 mm ø exhaust ducting has to be used the reducing collar needs to be fitted into the exhaust socket on the motor unit See Installation Extrac tion for details Insert the plug connectors from the vapour canopy into the correspond ing couplings on the motor unit Insert the plug for mains connecti...

Страница 26: ...hose If 150 mm Ø exhaust ducting is to be used then use a sharp knife to cut off the ex haust stub of the vapour guide at the join Mount the control unit on the hooks in the retaining plate and secure on both sides to the lugs of the retaining plate using 3 5 x 9 5 screws Insert the plug connectors from the vapour canopy into the correspond ing couplings on the control unit Installation 26 ...

Страница 27: ...nect the cooker hood and the external fan Insert the plug for mains connection into its socket or connect up the fused unit Preparation for extraction Use the hose clip to secure the flex ible hose onto the vent socket for ex haust connection The top end is directed to the open air through a cut out in the wall or ceiling Complete venting installation See the section Connection for extrac tion Ins...

Страница 28: ...e firmly to the upper retaining plate at each side with two 3 9 x 7 5 screws Protective sheets for tower The paper protective sheets protect the extension piece from accidental scratching when the tower is being fitted They are removed when fitting is complete Fold the protective sheets at the top Remove the protective foil around the sticking points Stick the protective sheets on to the sides of ...

Страница 29: ...ver the extension piece Push the shaft down approx 1 cm into the vapour canopy Adjust the shaft Loosen and then remove the protec tive sheets Now secure the shaft on both sides with two 3 9 x 7 5 screws Cover the screw heads with the cover caps supplied Installation 29 ...

Страница 30: ... diameter of the duct ing if absolutely necessary e g where narrower ducting has already been installed Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connection When ducting is horizontal it must be laid to slope away at 1 cm per metre to ensure no condensate drains into ...

Страница 31: ...ing we recommend that a suitable condensate trap is also installed to col lect and evaporate any condensate which may occur When installing a condensate trap en sure that it is positioned vertically and if possible directly above the exhaust socket Installation extraction 31 ...

Страница 32: ...lat roof on pitched roof on in outside wall free choice X X X X X X Air through put unducted in practice pipe con nection 850 m3 h 730 m3 h Ø 150 mm 950 m3 h 780 m3 h Ø 150 mm 125 mm 950 m3 h 780 m3 h Ø 150 mm 125 mm 850 m3 h 730 m3 h Ø 150 mm 900 m3 h 720 m3 h Ø 150 mm 125 mm 850 m3 h 730 m3 h Ø 150 mm Nominal voltage AC 220 230 V 50 Hz Motor output 330 W 170 W 170 W 330 W 315 W 330 W Measured in...

Страница 33: ...structions for the wall fan Remove the four fixing screws and take off the housing lid Mark where the holes for the screws are to be drilled Then drill the holes and insert plugs Screw the housing together Position the interior telescopic part and insert foam into the intervening space Secure the stainless steel lid to the housing Fit the extraction flexible hose and connect the control cable conn...

Страница 34: ...ding to EN 61591 Extraction system ø 150 mm Level I 220 m3 h Level II 335 m3 h Level III 440 m3 h Intensive level 640 m3 h Extraction system ø 125 mm Level I 210 m3 h Level II 305 m3 h Level III 405 m3 h Intensive level 590 m3 h Unrestricted 690 m3 h For EX models the rated load and ex traction power will depend on the type of external fan fitted Technical data 34 ...

Страница 35: ......

Страница 36: ...M No 08 255 650 00 1299 Alteration rights reserved ...

Отзывы: