External fans
The types of appliance available are listed in the table below. For further details
please refer to the section on External Fans in the special book: Planning Informa-
tion on Extractor Systems.
Fan type:
Roof
ventilator
Roof-
ventilator
Outside
wall fan
Outside
wall fan
Extractor
fan
Extractor
fan (wall)
Model:
DV 1100
DV 1005/1
DV 1005/1G
AWG
1005/1
AWG
1005/1G
AWG 1100
ABLG 940/1
MG 1100
Dimensions:
width mm
depth mm
height mm
Ø 301
244
380
460
230
380
460
160
Ø 301
124
360
400
245
310
280-390
390
Installed:
on flat roof
on pitched
roof
on / in
outside wall
free choice
–
X
–
–
–
X
–
–
–
–
X
–
–
–
X
–
–
–
–
X
–
–
X
–
Air through-
put:
(unducted)
in practice *
pipe con-
nection
850 m
3
/h
730 m
3
/h
Ø 150 mm
950 m
3
/h
780 m
3
/h
Ø 150 mm/
125 mm
950 m
3
/h
780 m
3
/h
Ø 150 mm/
125 mm
850 m3/h
730 m3/h
Ø 150 mm
900 m
3
/h
720 m
3
/h
Ø 150 mm/
125 mm
850 m
3
/h
730 m
3
/h
Ø 150 mm
Nominal
voltage:
AC 220 /230 V 50 Hz
Motor
output:
330 W
170 W
170 W
330 W
315 W
330 W
* Measured in the following
built-in situation:
cooker hood, 90° bend,
4m extraction ducting, external fan.
External fans
25