Operating and Installation Instructions

..............................................................................................................................

Cooker Hood

DA   846-1 (Vented)

Q

Содержание Imperial DA 846-1

Страница 1: ...Operating and Installation Instructions Cooker Hood DA 846 1 Vented Q ...

Страница 2: ...lly 10 Run on option 11 Switching off 11 Switching the lighting on or off 11 Filter operating hours counter 12 Power cut 14 Cleaning and care Housing 15 Changing the compact light unit 17 After sales service 18 Electrical connection 19 Installation Dimensions for building in 21 Building in 22 Depth alignment 24 Fitting the shelf 25 Preparation for extraction 25 Installation extraction Connection f...

Страница 3: ... children Danger of suffocation Rather than just throwing these ma terials away please ensure they are of fered for recycling Disposal of your old appliance Old appliances contain materials which can be reclaimed or recycled Please contact your dealer your waste collec tion centre or scrap merchant about potential recycling schemes Ensure that the appliance presents no danger to children while bei...

Страница 4: ...Guide to the appliance Guide to the appliance 4 ...

Страница 5: ...ill switch off automati cally i Automatic touch control This control selects and de selects Automatic operation in which drawing the vapour guide down or pushing it back up alters the fan power level j Grease filter touch control This indicator lamp for the grease filter touch control lights up when the grease filter needs to be cleaned The touch control is used to count down the time which is sho...

Страница 6: ...nd directed outside The cooker hood is fitted with a non return flap This flap is closed when the cooker hood is switched off No exchange of room air and outside air can take place When the cooker hood is switched on the non return flap opens for the cooking smells to be blown di rectly outside Description of the functions 6 ...

Страница 7: ...safety of this ap pliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system which complies with local and national regulations It is most import ant that this basic safety requirement is tested by a qualified electrician The manufacturer cannot be held re sponsible for the consequences of an inadequate earthing system e g elec tric shock Inst...

Страница 8: ...sy filter is a fire hazard Under no circumstances use a steam cleaner to clean this ap pliance Pressurised steam could reach the electrical components and cause a short circuit Installation The cooker hood can only be in stalled above an electric hob Safety regulations prohibit the fitting of this cooker hood over a gas hob a solid fuel stove or an open grill elec tric The distance between the top...

Страница 9: ... that the extractor can only be switched on when the heating ap pliance is switched off or vice versa N B The overall ventilation condition of the dwelling must be taken into ac count If in any doubt the advice of a compe tent builder or for gas a Corgi instal ler must be sought In countries which may be subject to infestation by cockroaches or other vermin pay particular attention to keeping the ...

Страница 10: ... power level touch control To switch on again press the right hand side of the control Selecting the power level Depending on how much the air needs to be filtered there are four power le vels available For normal cooking a low to medium level is usually suffi cient For frying or cooking food with a strong aroma the fourth level intensive setting is recommended Setting the power level manually low...

Страница 11: ...time Press twice 15 minutes run on time Press 3 times switch off The relevant indicator lamp glows to confirm the time selected To deactivate the run on option time press the run on option touch control until both the control lamps go out Switching off You can switch the fan off by either repeatedly pressing the left hand side of the power control until all the indicator lamps go out or retracting...

Страница 12: ... counter must be re set To do this press the grease filter touch control and hold for about 4 seconds The indicator lamp will go out Reading the filter operating hours counter To check the percentage of time set al ready used Switch the fan on Press the grease filter touch control One or several of the power level touch controls will flash The number of flashing lamps shows the percentage of the o...

Страница 13: ...rom 20 30 40 or 50 hours Pull down the vapour guide into the fan position Switch off the fan by pressing the left hand side of the power level touch control Press the run on and grease filter touch controls at the same time The indicator lamp for the grease filter touch control and one of the control lamps for the power level touch control will flash The power level touch control lamps show the ti...

Страница 14: ...vapour guide is pulled down the Automatic function is cancelled Restore as follows Push the vapour guide right back in until a resistance is felt Draw the vapour guide back down again until the desired power level position is reached Operation 14 ...

Страница 15: ...a cleaner which scours or contains chlorine acids or soda These would damage the surface of the cooker hood Grease filters Re usable metal grease filters are fitted which remove solid particles oil dust etc from the kitchen vapours prevent ing soiling of the cooker hood The grease filters should be cleaned regularly to avoid a build up of fat ap prox 3 4 weeks on average but sooner if necessary Al...

Страница 16: ...on of the surface of the filters However this will not affect the functioning of the grease filters in any way After cleaning leave the filters to dry for a while on an absorbent surface before putting it back in place When removing the filters for clean ing also clean off any residues of oil or fat from the now accessible hous ing to prevent the risk of these catch ing fire After putting the grea...

Страница 17: ... as ap propriate See Warning and Safety instructions Unscrew and remove the securing screw on the lamp cover Take the lamp cover off downwards at an angle Carefully guide the compact light downards b and pull out towards the front c Change the lamp 11W and fit the new one Screw the lamp cover back in place Cleaning and care 17 ...

Страница 18: ...e Dept see ad dress on back page When contacting the Service Depart ment please quote the Model and Ser ial number of your appliance both of which are given on the data plate which is located on the front of the housing Please note that telephone calls may be monitored and recorded to improve our service After sales service 18 ...

Страница 19: ...tion must be provided for all poles For extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA in accordance with DIN VDE 0664 Important The wires in the mains lead are col oured in accordance with the following code Green yellow earth Blue neutral Brown live If the appliance is to be connected via a plug and socket please note the fol lowing As the colo...

Страница 20: ...and on no account be in serted into any socket elsewhere in the house electric shock hazard The fuse cover must be re fitted when changing the fuse and if the fuse cover is lost the plug must not be used until a suitable replacement is obtained The colour of the correct replacement cover is that of the coloured insert in the base of the plug as applicable to the design of plug fitted The correct f...

Страница 21: ...rohibit the fitting of this cooker hood over a gas hob an open grill electric or a solid fuel stove The distance between the top of the hob and the bottom of the cooker hood when the vapour guide is completely retracted must measure at least 50 cm Dimensions for building in Installation 21 ...

Страница 22: ...he left and right of the appliance Position the non return unit in the vent socket so that the flaps can open upwards The cooker hood must only be lifted by the main body and not by the va pour guide Push the cooker hood into the wall unit from the front and hang on the support tracks Screw in the allen bolts on both sides with an allen key To adjust the height turn the allen bolts clockwise or an...

Страница 23: ...all unit on both sides at the lower edge of the body 19 mm thick unit sides 16 mm thick unit sides Screw the cooker hood securely to the wall unit to the support tracks on each side with the 3 5 x 16 mm screws Use washers with 16 mm unit sides Installation 23 ...

Страница 24: ...Depth alignment Units deeper than 285 mm require the fitting of a spacer bar to prevent va pours collecting between the rear of the cooker hood and the wall Shorten the spacer bar to the appro priate length at the required break ing point Put the spacer bar on the guide rail which is fitted to the rear lower edge of the body Installation 24 ...

Страница 25: ...helf Push the shelf with the punched edge pointing upwards between the guide lugs Secure the shelf with two screws Preparation for extraction For exhaust connection push the ducting on to the vent socket of the cooker hood Complete venting installation see section Connection for extraction Installation 25 ...

Страница 26: ...el of the cooker hood would increase and extraction would be less efficient Only reduce the diameter of the duct ing if absolutely necessary e g where narrower ducting has already been in stalled Only use wide radius bends Tight bends reduce the air throughput of the cooker hood Only use smooth pipes or flexible hoses made from non flammable ma terials for extraction connection When ducting is hor...

Страница 27: ...d to be addressed The exhaust ducting will need to be suitably insulated Condensate trap In addition to insulating the exhaust ducting we recommend that a suitable condensate trap is also installed to col lect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust socket Installation extracti...

Страница 28: ...d load 212 W Motor 190 W Lighting 2 x 11 W Voltage 230 V Frequency 50 Hz Fusing 13 A G B Fan power Extraction according to EN 61591 Level 1 3 150 430 m3 h Level 4 Intensive 550 m3 h unrestricted 720 m3 h Technical data 28 ...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...M No 8 257 040 00 1000 Alteration rights reserved ...