The rotary iron should be installed by a
Miele trained installer.
Installation site
,
Do not operate the rotary iron in a
room where cleaning machines are
operated with solvents containing CFC.
These vapors could damage the machine.
The machine does not require any special
anchorage or base installation.
^
Select a location which has sufficient light
for comfortable operation.
Installation
^
Level the rotary iron with the 4 height
adjustable feet. Hold the level on the front
and side columns.
Air extraction
^
The on-site ducting must not be connected
to a chimney which is used by gas, solid
fuel or oil fire boilers. It must be kept
separate from any dryer exhaust system.
^
The warm, moist exhaust should be
discharged outside by the shortest route
possible.
^
To ensure optimum air flow, the ducting
should contain as few bends as possible
and airtight connections.
^
Cover the open end at the outside with a
weather hood.
Condensate trap
A condensate trap must be installed at the
lowest point to prevent condensation from
collecting in the duct.
Installation instructions
16
Содержание HM 5316
Страница 15: ...Installation Instructions ...
Страница 19: ...19 ...
Страница 20: ...20 ...
Страница 21: ...21 ...
Страница 22: ...All rights reserved 2509 06 858 370 01 ...