,
All electrical work must be
carried out by a suitably qualified
and competent person in
accordance with local and national
safety regulations.
^
Connection should be made via a
suitable isolator, with an on-off switch
which should be easily accessible for
servicing work.
^
For extra safety it is advisable to
install a residual current device with a
trip current of 30 mA (in accordance
with DIN VDE 0664).
WARNING
THIS APPLIANCE MUST BE
EARTHED
^
Equipotential bonding should be
carried out.
Bonding connection
There is a screw connection point
marked with the earth symbol (
8
) at
the back of the machine, to which the
earth lead must be connected.
^
For technical data see data plate or
wiring diagram supplied.
The machine must only be operated
with the voltage, frequency and fusing
shown on the data plate.
This machine
can be converted
in
accordance with the conversion
diagram and wiring diagram supplied.
The conversion diagram and data plate
with test certification (VDE, DVGW etc.)
is located on the rear of the machine,
and on the plinth (behind the service
panel).
The wiring diagram is secured to the
inner side of the service panel.
To remove the service panel and
plinth:
,
Disconnect the machine from the
mains electricity supply.
^
Remove fixing screws
a
from the
service panel.
^
Take hold of the service panel at both
sides and pull upwards.
^
Unscrew plinth facing (screws
b
).
^
Remove the plastic protective cap.
Electrical connection
47
Содержание G 7860
Страница 27: ...27 ...